Yamaha EF2000iS Owners Manual - Page 23
Battery Charging, automatically if - generator manual
View all Yamaha EF2000iS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Battery Charging TIP 9 The generator DC rated voltage is 12V. 9 Start the engine first, and then connect the gener- ator to the battery for charging. 9 Before starting to charge the battery, make sure that the DC protector is turned on. 2 1 1 Red wire 2 Black wire 1. Start the engine. 2. Connect the red battery charger lead to the posi- 762-040 tive (+) battery terminal. 3. Connect the black battery charger lead to the neg- ative (-) battery terminal. 4. Turn the economy control switch off to start battery charging. NOTICE 6v 6v 12v 762-041 9 Be sure the economy control switch is turned off while charging the battery. 9 Be sure to connect the red battery charger lead to the positive (+) battery terminal, and connect the black lead to the negative (-) battery termi- nal. Do not reverse these positions. 9 Connect the battery charger leads to the bat- tery terminals securely so that they are not dis- connected due to engine vibration or other dis- turbances. 9 Charge the battery in the correct procedure by following instructions in the owner's manual for the battery. 9 The DC protector turns off 2 automatically if current above the rated flows during battery 21 7DK-052 charging. To restart charging the battery, turn the DC protector on by pressing its button to "ON" 1. If the DC protector turns off again, stop charging the battery immediately and consult a Yamaha dealer. 1 "ON" 2 "OFF" - 18 -