Yamaha LS9-32 Owner's Manual - Page 260

MIDI Data Format, CHANNEL MESSAGE

Page 260 highlights

MIDI Data Format MIDI Data Format This section explains the format of the data that the LS9 is able to understand, send, and receive. 1 CHANNEL MESSAGE 1.1 NOTE OFF (8n) Reception These messages are echoed to MIDI OUT if [OTHER COMMAND ECHO] is ON. They are received if [Rx CH] matches, and used to control effects. STATUS DATA 1000nnnn 8n Note off message 0nnnnnnn nn Note number 0vvvvvvv vv Velocity(ignored) 1.2 NOTE ON (9n) Reception These messages are echoed to MIDI OUT if [OTHER COMMAND ECHO] is ON. They are received if [Rx CH] matches, and used to control effects. STATUS DATA 1001nnnn 9n Note on message 0nnnnnnn nn Note number 0vvvvvvv vv Velocity (1-127:on, 0:off) 1.3 CONTROL CHANGE (Bn) Two types of CONTROL CHANGE can be transmitted and received; [NRPN] (Non-Registered Parameter Numbers) and freely-assigned [TABLE] (1CH x 110) messages. Select either [TABLE] or [NRPN]. Reception These messages are echoed to MIDI OUT if [CONTROL CHANGE ECHO] is ON. If [TABLE] is selected, these messages are received when [CONTROL CHANGE Rx] is ON and [Rx CH] matches, and will control parameters according to the settings of the [CONTROL CHANGE EVENT LIST]. For the parameters that can be assigned, refer to "Parameters that can be assigned to control changes" on page 249. If [NRPN] is selected, these messages are received when [CONTROL CHANGE Rx] is ON and the [Rx CH] matches; the four messages NRPN control number (62h, 63h) and DATA ENTRY control number (06h, 26h) are used to control the specified parameter. Transmission If [TABLE] is selected, and if [CONTROL CHANGE Tx] is ON when you operate a parameter that is assigned in the [CONTROL CHANGE EVENT LIST], these messages will be transmitted on the [Tx CH] channel. For the parameters that can be assigned, refer to "Parameters that can be assigned to control changes" on page 249. If [NRPN] is selected, and if [CONTROL CHANGE Tx] is ON when you operate a specified parameter, the four messages NRPN control number (62h, 63h) and DATA ENTRY control number (06h, 26h) are transmitted on the [Tx CH] channel. For the parameters that can be assigned, refer to "Parameters that can be assigned to control changes" on page 249. CONTROL CHANGE messages are not used for transmission to LS9 Editor because there is no guarantee that the contents of the assignment tables will match. (PARAMETER CHANGE messages are always used.) CONTROL CHANGE numbers 0 and 32 are for selecting banks. STATUS DATA STATUS DATA 1011nnnn Bn Control change 00 Control number (00) 0vvvvvvv vv Control Value (0-127) 1011nnnn Bn Control change 20 Control number (32) 0vvvvvvv vv Control Value (0-127) If [TABLE] is selected STATUS 1011nnnn Bn Control change DATA 0nnnnnnn nn Control number (1-5, 7-31, 33-37, 38-95, 102-119) * 0vvvvvvv vv Control Value (0-127) * Numbers 0, 32, and 96-101 cannot be used. * Control number 6, 38 can be used. Equation for converting a Control Value to parameter data paramSteps add mod curValue = paramMax-paramMin + 1; = paramWidth / paramSteps; = paramWidth-add * paramSteps; = paramSteps * add + mod / 2; (1) If the assigned parameter has fewer than 128 steps paramWidth = 128; rxValue = Control value; (2) If the assigned parameter has 128 or more but less than 16,384 steps paramWidth = 16384; (2-1) When High and Low data is received rxValue = Control value(High) * 128 + Control value(Low); (2-2) When only Low data is received rxValue = (curValue & 16256) + Control value(Low); (2-3) When only High data is received rxValue = Control value(High) * 128 + (curValue & 127); (3) If the assigned parameter has 16,384 or more but less than 2,097,152 steps paramWidth = 2097152; (3-1) When High, Middle, and Low data is received rxValue = Control value(High) * 16384 + Control value(Middle) * 128 + Control value(Low); (3-2) When only Low data is received rxValue = (curValue & 2097024) + Control value(Low); (3-3) When only Middle data is received rxValue = (curValue & 2080895) + Control value(Middle) * 128; (3-4) When only High data is received rxValue = (curValue & 16383) + Control value(High) * 16384; (3-5) When only Middle and Low data is received rxValue = (curValue & 2080768) + Control value(Middle) * 128 + Control value(Low); (3-6) When only High and Low data is received rxValue = (curValue & 16256) + Control value(High) * 16384 + Control value(Low); (3-7) When only High and Middle data is received rxValue = (curValue & 127) + Control value(High) * 16384 + Control value(Middle) * 128; if ( rxValue > paramWidth) rxValue = paramWidth; param = ( rxValue-mod / 2) / add; If [NRPN] is selected STATUS 1011nnnn Bn Control change DATA 01100010 62 NRPN LSB 0vvvvvvv vv Parameter number LSB STATUS 1011nnnn Bn Control change * DATA 01100011 63 NRPN MSB 0vvvvvvv vv Parameter number MSB STATUS 1011nnnn Bn Control change * DATA 00000110 06 Data entry MSB 0vvvvvvv vv Parameter data MSB STATUS 1011nnnn Bn Control change * DATA 00100110 26 Data entry LSB 0vvvvvvv vv Parameter data LSB * The STATUS byte of the second and subsequent messages need not be added during transmission. Reception must occur correctly whether or not the status byte is omitted. 260 LS9-16/32 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290

MIDI Data Format
260
LS9-16/32
Owner’s Manual
This section explains the format of the data that the LS9 is able to understand, send, and receive.
1
CHANNEL MESSAGE
1.1
NOTE OFF
(8n)
Reception
These messages are echoed to MIDI OUT if [OTHER COMMAND ECHO] is
ON.
They are received if [Rx CH] matches, and used to control effects.
1.2
NOTE ON
(9n)
Reception
These messages are echoed to MIDI OUT if [OTHER COMMAND ECHO] is
ON.
They are received if [Rx CH] matches, and used to control effects.
1.3
CONTROL CHANGE
(Bn)
Two types of CONTROL CHANGE can be transmitted and received; [NRPN]
(Non-Registered Parameter Numbers) and freely-assigned [TABLE] (1CH x
110) messages. Select either [TABLE] or [NRPN].
Reception
These messages are echoed to MIDI OUT if [CONTROL CHANGE ECHO] is
ON.
If [TABLE] is selected, these messages are received when [CONTROL CHANGE
Rx] is ON and [Rx CH] matches, and will control parameters according to the
settings of the [CONTROL CHANGE EVENT LIST]. For the parameters that
can be assigned, refer to “Parameters that can be assigned to control changes” on
page 249.
If [NRPN] is selected, these messages are received when [CONTROL CHANGE
Rx] is ON and the [Rx CH] matches; the four messages NRPN control number
(62h, 63h) and DATA ENTRY control number (06h, 26h) are used to control the
specified parameter.
Transmission
If [TABLE] is selected, and if [CONTROL CHANGE Tx] is ON when you
operate a parameter that is assigned in the [CONTROL CHANGE EVENT
LIST], these messages will be transmitted on the [Tx CH] channel. For the
parameters that can be assigned, refer to “Parameters that can be assigned to
control changes” on page 249.
If [NRPN] is selected, and if [CONTROL CHANGE Tx] is ON when you
operate a specified parameter, the four messages NRPN control number (62h,
63h) and DATA ENTRY control number (06h, 26h) are transmitted on the [Tx
CH] channel. For the parameters that can be assigned, refer to “Parameters that
can be assigned to control changes” on page 249.
CONTROL CHANGE messages are not used for transmission to LS9 Editor
because there is no guarantee that the contents of the assignment tables will
match. (PARAMETER CHANGE messages are always used.)
CONTROL CHANGE numbers 0 and 32 are for selecting banks.
If [TABLE] is selected
Equation for converting a Control Value to parameter data
paramSteps
= paramMax–paramMin + 1;
add
= paramWidth / paramSteps;
mod
= paramWidth–add * paramSteps;
curValue
= paramSteps * add + mod / 2;
(1) If the assigned parameter has fewer than 128 steps
paramWidth = 128; rxValue = Control value;
(2) If the assigned parameter has 128 or more but less than
16,384 steps
paramWidth = 16384;
(2-1) When High and Low data is received
rxValue = Control value(High) * 128 + Control value(Low);
(2-2) When only Low data is received
rxValue = (curValue & 16256) + Control value(Low);
(2-3) When only High data is received
rxValue = Control value(High) * 128 + (curValue & 127);
(3) If the assigned parameter has 16,384 or more but less than
2,097,152 steps
paramWidth = 2097152;
(3-1) When High, Middle, and Low data is received
rxValue = Control value(High) * 16384 + Control value(Middle) * 128 + Control
value(Low);
(3-2) When only Low data is received
rxValue = (curValue & 2097024) + Control value(Low);
(3-3) When only Middle data is received
rxValue = (curValue & 2080895) + Control value(Middle) * 128;
(3-4) When only High data is received
rxValue = (curValue & 16383) + Control value(High) * 16384;
(3-5) When only Middle and Low data is received
rxValue = (curValue & 2080768) + Control value(Middle) * 128 + Control
value(Low);
(3-6) When only High and Low data is received
rxValue = (curValue & 16256) + Control value(High) * 16384 + Control value(Low);
(3-7) When only High and Middle data is received
rxValue = (curValue & 127) + Control value(High) * 16384 + Control value(Middle)
* 128;
if ( rxValue > paramWidth)
rxValue = paramWidth;
param = ( rxValue–mod / 2) / add;
If [NRPN] is selected
MIDI Data Format
STATUS
1000nnnn 8n
Note off message
DATA
0nnnnnnn nn
Note number
0vvvvvvv vv
Velocity(ignored)
STATUS
1001nnnn 9n
Note on message
DATA
0nnnnnnn nn
Note number
0vvvvvvv vv
Velocity (1-127:on, 0:off)
STATUS
1011nnnn Bn
Control change
DATA
00
Control number (00)
0vvvvvvv vv
Control Value (0-127)
STATUS
1011nnnn Bn
Control change
DATA
20
Control number (32)
0vvvvvvv vv
Control Value (0-127)
STATUS
1011nnnn Bn
Control change
DATA
0nnnnnnn nn
Control number (1-5, 7-31, 33-37, 38-95,
102-119) *
0vvvvvvv vv
Control Value (0-127)
*
Numbers 0, 32, and 96–101 cannot be used.
*
Control number 6, 38 can be used.
STATUS
1011nnnn Bn
Control change
DATA
01100010 62
NRPN LSB
0vvvvvvv vv
Parameter number LSB
STATUS
1011nnnn Bn
Control change *
DATA
01100011 63
NRPN MSB
0vvvvvvv vv
Parameter number MSB
STATUS
1011nnnn Bn
Control change *
DATA
00000110 06
Data entry MSB
0vvvvvvv vv
Parameter data MSB
STATUS
1011nnnn Bn
Control change *
DATA
00100110 26
Data entry LSB
0vvvvvvv vv
Parameter data LSB
*
The STATUS byte of the second and subsequent messages need not
be added during transmission. Reception must occur correctly
whether or not the status byte is omitted.