Yamaha Tio1608-D2 Tio1608-D2 Owners Manual - Page 15

Manual setup, Head amp control, Settings con d by Quick Config, Tio1608-D2 procedure

Page 15 highlights

Connection methods English 7. To assign the Tio1608-D2 inputs to the TF series mixing console, set the input select on the console's INPUT screen to "SLOT". NOTE While the INPUT screen is displayed, the menu keys can be used to change multiple currently selected FADER BANK inputs at the same time. 8. Adjust the input gain and other settings as necessary. Quick config is now complete. Settings configured by Quick Config Quick Config applies the following settings. • Dante settings Word clock Latency Encoding SECONDARY port mode Patching IP address 48 kHz (follower), no pull up/down 0.5 ms 24-bit PCM Daisy chain Refer to the table below Previous setting is used NOTE Quick Config does not configure analog input parameters. • Patching Tio input #1 ID 1, Input 1 ID 1, Input 2 : ID 1, Input 16 TF input  Channel 1  Channel 2 :  Channel 16 #2 ID 2, Input 1 ID 2, Input 2 : ID 2, Input 16  Channel 17  Channel 18 :  Channel 32 #3 ID 3, Input 1 ID 3, Input 2 : ID 3, Input 8  Channel 33  Channel 34 :  Channel 40 TF output Tio output AUX 1  ID 1, Output 1 : : AUX 6 Stereo L  ID 1, Output 6  ID 1, Output 7 Stereo R AUX 7  ID 1, Output 8  ID 2, Output 1 : : AUX 12  ID 2, Output 6 Stereo L Stereo R AUX 13  ID 2, Output 7  ID 2, Output 8  ID 3, Output 1 : AUX 18 AUX 19 AUX 20 :  ID 3, Output 6  ID 3, Output 7  ID 3, Output 8 NOTE • Even if only UNIT ID 2 or 3 is used, channels are patched as shown above based on the UNIT ID number. • After you have used Quick Config to configure the settings, you can use Dante Controller to change the individual settings. However, each time the Tio1608-D2 is turned on, Dante Controller settings will be replaced by the Quick Config settings. For this reason, we recommend that you turn Quick Config off if you are using Dante Controller. Manual setup If Quick Config is not used or if connecting to a mixer that does not support Quick Config, configure settings manually based on the given connection environment. Tio1608-D2 procedure 1. With the unit turned off, set the [QUICK CONFIG FOR TF] on the front panel to the [OFF] position. 2. Refer to the information on page 11 - 12 and set the DIP switches to the desired positions. 3. Set the [UNIT ID] on the front panel to the desired position. 4. Use Ethernet cables to connect the Tio1608-D2 to your Dante device. 5. Turn each device on. Dante settings When using manual setup, use Dante Controller to configure Dante settings. Dante Controller is a computer program that you can use to configure Dante network settings and audio signal patching settings. To use the program, download it from the Audinate website. (Dante Controller v3.2.1 or later is compatible with Tio1608-D2.) For information about Dante Controller, refer to the Dante Controller documentation. When using manual setup, you will need to use Dante Controller to configure the following settings at a minimum. (You can configure other settings as desired.) • Input and output patching settings (Network View  Routing) • Clock leader settings (Network View  Clock Status) • Sampling frequency settings (Device View  Config) Head amp control You can use a Yamaha digital mixer or other device to control the Tio1608-D2 head amp. When the unit is connected to a TF series mixing console, you can control the unit's head amp just as you would adjust the console's head amp. When using a CL or QL series digital mixer, you can control or use the following parameters. • HA gain • +48 V phantom power on/off • HPF on/off • HPF frequency cutoff adjustment • Mute off • +48 V phantom power on/off display • Analog input level meter display • Firmware version display • Device identify • Dante SYSTEM and SYNC indicator information NOTE When the Dante SECONDARY port mode (page 12) is set to "Redundant connection", the head amp control function is only available via the Dante [PRIMARY]. The Dante [SECONDARY] is not available for this function. - 15 - Tio1608-D2 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Connection methods
-
15
-
Owner’s Manual
Tio1608-D2
English
7.
To assign the Tio1608-D2 inputs to the TF series
mixing console, set the input select on the console's
INPUT screen to "SLOT".
8.
Adjust the input gain and other settings as
necessary.
Q
u
ick config is no
w
complete.
Settings configured by Quick Config
Q
u
ick Config applies the follo
w
ing settings.
Dante settings
• Patching
Manual setup
If Q
u
ick Config is not
u
sed or if connecting to a mixer that
does not s
u
pport Q
u
ick Config, config
u
re settings man
u
ally
based on the given connection environment.
Tio1608-D2 procedure
1.
With the unit turned off, set the [QUICK CONFIG FOR
TF] on the front panel to the [OFF] position.
2.
Refer to the information on
page 11 - 12
and set the
DIP switches to the desired positions.
3.
Set the [UNIT ID] on the front panel to the desired
position.
4.
Use Ethernet cables to connect the Tio1608-D2 to
your Dante device.
5.
Turn each device on.
Dante settings
When
u
sing man
u
al set
u
p,
u
se Dante Controller to
config
u
re Dante settings.
Dante Controller is a comp
u
ter program that yo
u
can
u
se to
config
u
re Dante net
w
ork settings and a
u
dio signal patching
settings. To
u
se the program, do
w
nload it from the A
u
dinate
w
ebsite. (Dante Controller v3.2.1 or later is compatible
w
ith
Tio160
8
-D2.)
For information abo
u
t Dante Controller, refer to the Dante
Controller doc
u
mentation.
When
u
sing man
u
al set
u
p, yo
u
w
ill need to
u
se Dante
Controller to config
u
re the follo
w
ing settings at a minim
u
m.
(Yo
u
can config
u
re other settings as desired.)
• Inp
u
t and o
u
tp
u
t patching settings (
N
et
w
ork Vie
w
Ro
u
ting)
Clock leader settings (
N
et
w
ork Vie
w
Clock Stat
u
s)
Sampling freq
u
ency settings (Device Vie
w
Config)
Head amp control
Yo
u
can
u
se a Yamaha digital mixer or other device to
control the Tio160
8
-D2 head amp.
When the
u
nit is connected to a TF series mixing console,
yo
u
can control the
u
nit's head amp j
u
st as yo
u
w
o
u
ld adj
u
st
the console's head amp.
When
u
sing a CL or QL series digital mixer, yo
u
can control
or
u
se the follo
w
ing parameters.
HA gain
• +4
8
V phantom po
w
er on/off
HPF on/off
HPF freq
u
ency c
u
toff adj
u
stment
•M
u
te off
• +4
8
V phantom po
w
er on/off display
Analog inp
u
t level meter display
• Firm
w
are version display
Device identify
Dante SYSTEM and SY
N
C indicator information
NOTE
While the I
N
PUT screen is displayed, the men
u
keys can be
u
sed to change m
u
ltiple c
u
rrently selected FADER BA
N
K
inp
u
ts at the same time.
Word clock
48 kHz (follower), no pull up/down
Latency
0.5 ms
Encoding
24-bit PCM
SECONDARY port mode
Daisy chain
Patching
Refer to the table below
IP address
Previous setting is used
NOTE
Q
u
ick Config does not config
u
re analog inp
u
t parameters.
Tio input
TF input
TF output
Tio output
#1
ID 1, Input 1
Channel 1
AUX 1
ID 1, Output 1
ID 1, Input 2
Channel 2
:
:
:
:
AUX 6
ID 1, Output 6
ID 1, Input 16
Channel 16
Stereo L
ID 1, Output 7
Stereo R
ID 1, Output 8
#2
ID 2, Input 1
Channel 17
AUX 7
ID 2, Output 1
ID 2, Input 2
Channel 18
:
:
:
:
AUX 12
ID 2, Output 6
ID 2, Input 16
Channel 32
Stereo L
ID 2, Output 7
Stereo R
ID 2, Output 8
#3
ID 3, Input 1
Channel 33
AUX 13
ID 3, Output 1
ID 3, Input 2
Channel 34
:
:
:
:
AUX 18
ID 3, Output 6
ID 3, Input 8
Channel 40
AUX 19
ID 3, Output 7
AUX 20
ID 3, Output 8
NOTE
Even if only U
N
IT ID 2 or 3 is
u
sed, channels are patched as
sho
w
n above based on the U
N
IT ID n
u
mber.
After yo
u
have
u
sed Q
u
ick Config to config
u
re the settings, yo
u
can
u
se Dante Controller to change the individ
u
al settings.
Ho
w
ever, each time the Tio160
8
-D2 is t
u
rned on, Dante
Controller settings
w
ill be replaced by the Q
u
ick Config settings.
For this reason,
w
e recommend that yo
u
t
u
rn Q
u
ick Config off if
yo
u
are
u
sing Dante Controller.
NOTE
When the Dante SECO
N
DARY port mode (
page 12
) is set to
"Red
u
ndant connection", the head amp control f
u
nction is only
available via the Dante [PRIMARY]. The Dante [SECO
N
DARY] is
not available for this f
u
nction.