Yamaha XM4180 Owner's Manual - Page 15

Current Draw, XM4180, XH200

Page 15 highlights

■ Current Draw XM4180 standby idle 1/8 power 8Ω/ch 4Ω/ch 1/3 power 8Ω/ch 4Ω/ch Line Current (A) 100/120V 230/240V 0.08 0.04 1.0 0.5 4.8 2.6 6.8 3.7 11.3 6.2 15.9 8.8 In 5 40 327 460 793 1115 Power (W) Out 0 0 90 115 240 307 Dissipated 5 40 237 345 553 808 XM4080 standby idle 1/8 power 8Ω/ch 4Ω/ch 1/3 power 8Ω/ch 4Ω/ch Line Current (A) 100/120V 230/240V 0.08 0.04 1.0 0.5 2.8 1.5 4.5 2.4 6.8 3.7 10.5 5.8 In 5 40 191 303 464 734 Power (W) Out 0 0 40 58 107 153 Dissipated 5 40 151 245 357 580 XH200 standby idle 1/8 power Line Current (A) 100/120V 230/240V 0.08 0.04 1.0 0.5 3.7 2.0 In 5 40 250 Power (W) Out 0 0 50 Dissipated 5 40 200 1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications. 1/3 power represents program material with extremely heavy clipping. Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz 1W = 0.860kcal/h, 1BTU = 0.252kcal Note that Line Voltage [V] x Line Current [A] = [VA], not equals to [W]. Inrush current: 11A (100V), 13A (120V), 25A (240V) Thermal Dissipation Btu/h kcal/h 17 4 137 34 810 204 1180 297 1890 476 2760 695 Thermal Dissipation Btu/h kcal/h 17 4 137 34 517 130 837 211 1220 307 1980 499 Thermal Dissipation Btu/h kcal/h 17 4 137 34 683 172 XM4180/XM4080/XH200 Owner's Manual 15 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

XM4180/XM4080/XH200 Owner’s Manual
15
Current Draw
XM4180
XM4080
XH200
1/8 power is typical of program material with occasional clipping. Refer to these figures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h,
1BTU = 0.252kcal
Note that Line Voltage [V]
x Line Current [A] = [VA], not equals to [W].
Inrush current: 11A (100V), 13A (120V), 25A (240V)
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
standby
0.08
0.04
5
0
5
17
4
idle
1.0
0.5
40
0
40
137
34
1/8 power
8
/ch
4.8
2.6
327
90
237
810
204
4
/ch
6.8
3.7
460
115
345
1180
297
1/3 power
8
/ch
11.3
6.2
793
240
553
1890
476
4
/ch
15.9
8.8
1115
307
808
2760
695
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
standby
0.08
0.04
5
0
5
17
4
idle
1.0
0.5
40
0
40
137
34
1/8 power
8
/ch
2.8
1.5
191
40
151
517
130
4
/ch
4.5
2.4
303
58
245
837
211
1/3 power
8
/ch
6.8
3.7
464
107
357
1220
307
4
/ch
10.5
5.8
734
153
580
1980
499
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
standby
0.08
0.04
5
0
5
17
4
idle
1.0
0.5
40
0
40
137
34
1/8 power
3.7
2.0
250
50
200
683
172
43