Zanussi ZCG63050WA User Manual - Page 22
Other Technical Data, Warning, Gas Burners, Burner, Normal Power Kw, Natural Gas, Injector Mark 1/
View all Zanussi ZCG63050WA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
180 mm 30 mm GAS BURNERS OTHER TECHNICAL DATA WARNING! These instructions are only valid in the countries whose symbols appear on this booklet's cover. Gas category: Gas supply: Voltage: Frequency: I2H G20 (2H) 20 mbar 220-240 V 50 Hz BURNER NORMAL POWER kW Natural Gas INJECTOR MARK 1/100 mm Btu/h Auxiliary 1 Semi-rapid 1.9 Rapid 3 Top Oven 1.7 Main Oven 1.7 GAS CONNECTION Use a flexible pipe in compliance with the regulation in force. Make sure they do not come in touch with mobile parts and are not squeezed. WARNING! Only a qualified and competent person can do the gas installation. Before you connect te gas, disconnect the appliance from the electricity supply or switch off the fuse in the fuse box. Close the primary valve of the gas supply. Supply piping should not be less than R3/8. Connection is made to the Rc 1/2 (1/2 " B.S.P.) female threaded. The entry pipe is located just below the hob level on the rear left hand side of the appliance. The gas supply ramp is on the rear side of the appliance. 70 3412 96 6483 119 10236 95 5804 95 5804 WARNING! Only liquid sealants can be used when the inlet gas pipe is fitted i.e.: do not use the P.T.F.E. sealant tape. When the installation is complete, carry out a gas tightness test and make sure that the seal of each pipe fitting does not leak. Use flexible tubing, which comply with the BS.669 current edition. 22