Installation
UPC - 016963541009
View all Zenith SL-5410-GR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
INSTALLATION Wire the Light Control For easy installation, select an existing light operated by a wall switch for replacement. For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance. ❒ Drill the holes needed to mount the backplate to the junction box. WARNING: Turn power off at circuit breaker or fuse. ❒ Remove the existing light fixture. ❒ Route the light control's wires through the large gasket hole. ❒ Connect the junction box wires to the light control wires. Twist together and secure with a wire connector. NOTICE: 5410 models with Flash Alert feature will also have a wire loop which can be used to disable the flash alert feature. This wire loop should not be connected to any other wire. White to White Black to Black Eave Mount Wall Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: ❒ Rotate the sensor head towards the clamp screw joint. Control Switch Gasket Flash Alert - Activated (Blue) Joint Clamp ❒ Then rotate the sensor head clockwise 180° so the controls face down. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. 598-1303-01