Zenith SL-5410-GR User Guide - Page 3
Test And Adjustment
UPC - 016963541009
View all Zenith SL-5410-GR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
To Deactivate the Flash Alert TEST AND ADJUSTMENT WARNING: Turn power off at circuit breaker or fuse. ❒ Remove the light fixture if necessary. ❒ Locate the (Blue) wire loop coming from the sensor inside the canopy. ❒ Cut the (Blue) wire loop. ❒ Securely attach wire nuts (supplied) to each of the cut ends of the (Blue) wire. DO NOT connect the wires together. ❒ Mount light control to wall or eave. ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes. ❒ Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position. ON-TIME SENS 10 5 1 TEST MIN MAX Bottom of Sensor Flash Alert - Deactivated (Blue) Mount the Light Control ❒ Align the light control cover plate and the junction box holes. Secure with the mounting screws. ❒ If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone. Avoid water damage and electrical shock - keep lamp holders below horizontal. Lock nuts Keep lamps at least 1" (25 mm) from the sensor. ❒ Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.When screwing in the floodlamps, do not overtighten. 598-1303-01