Zenith SL-6107-WH User Guide - Page 2

Installation - switch

Page 2 highlights

Some local building codes may require installation by a qualified electrician. INSTALLATION ❐ For your safety, turn off power at the fuse or circuit breaker. Note: A "3-way" circuit controls lights from two separate switches. If you want to use this product in a single switch circuit or if you want to install more than one motion sensing wall switch, see Special Installations, page 8. ❐ Select a 3-way circuit that controls a light or an outlet to a lamp. Total lighting must be from 25 to 500 watts incandescent, or 60 to 400 watts fluorescent using a rapid start ballast. Note: May not be used to operate electronic or magnetic ballasts. Less wattage than the minimum may not allow the control to work properly. The switch selected for replacement should be in a place that can detect motion in the desired area. ✓ For easier re-wiring later, mark the house wiring with tape indicating where the wire had been connected. In the following section you will install a jumper wire at one 3-way switch and replace the other switch with the SL-6107. *Note: The existing 3-way switch will be referred to as the "Remote Switch" throughout the rest of the installation manual. -- 595-4514-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

595-4514-15
-2-
Some local building codes may require installation by a quali-
fied electrician.
INSTALLATION
For your safety, turn off power at the fuse or circuit breaker.
Note:
A “3-way” circuit controls lights from two separate switches. If
you want to use this product in a single switch circuit or if you want
to install more than one motion sensing wall switch, see
Special
Installations,
page 8.
Select a 3-way circuit that controls a light or an outlet to a lamp.
Total lighting must be from
25 to 500 watts incandescent, or 60 to
400 watts fluorescent using a
rapid start ballast.
Note:
May not
be used to operate electronic or magnetic ballasts.
Less wattage
than the minimum may not allow the control to work properly. The
switch selected for replacement should be in a place that can detect
motion in the desired area.
For easier re-wiring later, mark the house wiring with tape
indicating where the wire had been connected.
In the following section you will install a jumper wire at one 3-way
switch and replace the other switch with the SL-6107.
*
Note:
The existing 3-way switch will be referred to as the “Remote
Switch” throughout the rest of the installation manual.