Cleaning The Heat Pump Filter
View all Asko T411HSW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
CLEANING THE HEAT PUMP FILTER Do not touch the inner metal parts of the heat exchanger with bare hands. Danger of injury on sharp parts. Use appropriate protection gloves when cleaning the heat exchanger. Incorrect cleaning of the metal fins of the heat exchanger can permanently damage the tumble dryer. Do not press on the metal fins with hard objects like for example the plastic tube of a vacuum cleaner. 1 During cleaning, some water may be spilled. It is therefore recommended to place an absorbent cloth on the floor. Open the outer cover. 2 Hold the levers on the inside cover and rotate them upwards. Remove the inside cover. 3 Use the handle to pull out the heat pump filter. 4 Pull the foam part of the heat pump filter from the housing. Wash it under running water and dry it before replacing it in the filter housing. The filter may be washed in the washing machine, with the rinse program on low spin speed. Dry the filter before replacing it in the filter housing. Clean the foam filter at least after every 10 drying cycles or if necessary. 34 Customer Care Center, 1-800-898-1879, www.askona.com