output 2: ON: ENABLING

Page 12 highlights

•Read the written data with the FD read icon. ,Display the enabling condition setting screen. Referring to the condition number table of the extended option output (see page 193), set the enabling condition of No. 1 to the condition No. 72 (output 2: ON): ENABLING ¡ and the condition No. 73 (output 2: OFF): DISABLING X by writing over the previous data. ƒReferring to the condition number table of the extended option external input (see page 192), set the output condition of No. 2 to ON when the condition No. 40 (input 1: ON) is set. Input on the setting screen as follows: „Referring to the condition number table of the extended option external input (see page 192), set the output condition of No. 2 to OFF when the condition No. 41 (input 1: OFF) is set. Input on the setting screen as follows: ...Referring to the condition number table of the extended option external input (see page 192), set the enabling condition of No. 2 to the condition No. 42 (input 2: ON): ENABLING ¡, and the condition No. 43 (input 2: OFF): DISABLING X. †After overwriting the option program to the FD, press the P key to turn off the display of the programmer, turn the power off and on again. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

12
±
Read the written data with the FD read icon.
²
Display the enabling condition setting screen. Referring to the condition number table of the
extended option output (see page 193), set the enabling condition of No. 1 to the condition No. 72
(output 2: ON): ENABLING
¡
and the condition No. 73 (output 2: OFF): DISABLING
X
by writing over
the previous data.
³
Referring to the condition number table of the extended option external input (see page 192), set the
output condition of No. 2 to ON when the condition No. 40 (input 1: ON) is set. Input on the setting
screen as follows:
´
Referring to the condition number table of the extended option external input (see page 192), set the
output condition of No. 2 to OFF when the condition No. 41 (input 1: OFF) is set. Input on the setting
screen as follows:
µ
Referring to the condition number table of the extended option external input (see page 192), set the
enabling condition of No. 2 to the condition No. 42 (input 2: ON): ENABLING
¡
, and the condition No.
43 (input 2: OFF): DISABLING
X
.
After overwriting the option program to the FD, press the P key to turn off the display of the
programmer, turn the power off and on again.