Brother International BAS-375E Extended Option Output Instruction Manual - Eng - Page 13
Emergency stop during sequence
View all Brother International BAS-375E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
‡Check that sewing starts when the work clamp descends when the option input No. 1 and No. 2 are ON. The output condition of the virtual output No. 2: ON is the condition No. 40 (input1: ON) as shown in the example above. If the input 1 has been ON since the power was turned ON, the virtual output No. 2 can not be ON. 3-4 Emergency stop during sequence Program the example 1 of the instruction manual and check the option output at emergency stop •Delete the registered option program with the delete icon, and turn the power off and on again. ,Following the example 1 (sequence 1 for stacker) of page 196 of the instruction manual for the programmer, program the output No. 4, 5, 6, and the enabling condition of No. 4. ƒIf the option output is operated as programmed, press the emergency stop SW during sequence operation. Emergency stop during sequence is a pause of sequence, and sequence is completed if emergency stop is canceled. „Add the condition No. 15 (after an emergency stop occurs) when the output No. 4, 5, and 6 are OFF. If the emergency stop SW is pressed, output are immediately turned OFF. 13