Input terminal

Page 14 highlights

4. Programming 4-1 Selecting hardware on output side Output is NPN open collector output. PCB internal circuit +24V COM terminal Load Output I = 70mA terminal On the assumption that output activates the air valve (option part). Use a 24 VDC relay if not using a 24 V air valve. PCB internal circuit External 24V relay +24V COM terminal Load L L Output terminal Power No fuses are built in the output circuit. To prevent circuit damage when forming short output, it is recommendable to install an external fuse on each output. 4-2 Selecting hardware on input side Input is non-insulating IC input. PCB internal circuit Example of connection with proximity sensor +5 +24V 4.7KΩ Input terminal 0V Vcc Sensor output Sensor output NPN open collector 0V Insulate input using a relay if not using a contact switch or a 24 V sensor. PCB internal circuit +5 +24V External relay 4.7KΩ Input terminal 0 External apparatu Use a relay for electronic circuit whose maximum applicable load is 5 V and 1m A or less. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

14
4.
Programming
4-1 Selecting hardware on output side
°
Output is NPN open collector output.
PCB internal circuit
°
On the assumption that output activates the air valve (option part).
°
Use a 24 VDC relay if not using a 24 V air valve.
PCB internal circuit
External 24V relay
°
No fuses are built in the output circuit. To prevent circuit damage when forming short output, it is
recommendable to install an external fuse on each output.
4-2 Selecting hardware on input side
°
Input is non-insulating IC input.
PCB internal circuit
Example of connection with proximity sensor
°
Insulate input using a relay if not using a contact switch or a 24 V sensor.
PCB internal circuit
External relay
°
Use a relay for electronic circuit whose maximum applicable load is 5 V and 1m A or less.
+24V
Load
I = 70mA
COM terminal
Output
terminal
+24V
Load
L
COM terminal
Output
terminal
Power
+24V
0V
+5
4.7K
W
Vcc
0V
Input terminal
Sensor output
Sensor output
NPN open collector
+24V
0
+5
4.7K
W
L
Input terminal
External
apparatu