Cisco VG202 Hardware Installation Guide - Page 25

Planning Your Installation, Location and Mounting Requirements, Temperature Control and Ventilation

Page 25 highlights

2 C H A P T E R Planning Your Installation Before you install your Cisco VG202 and Cisco VG204 voice gateways, consider the information in this chapter: • Location and Mounting Requirements, page 2-1 • Distance Limitations for Interface Cables, page 2-2 • Interference Considerations, page 2-3 Location and Mounting Requirements There are two ways of mounting the Cisco VG202 and Cisco VG204 voice gateways: • Wall mounting • Desktop mounting Whether wall or desktop, the mounting location must provide the following: • Access to the chassis • Access to a suitable power source • Access to an appropriate earth ground • Allowance for adequate heat dissipation and airflow around the chassis Temperature Control and Ventilation The installation area (room, closet, or cabinet) for the Cisco VG202 and Cisco VG204 voice gateways should always be well ventilated and should provide adequate air circulation to ensure proper cooling. The room temperature should be maintained from 32 to 122°F (0 to 50°C). Wall Mounting If the Cisco VG202 and Cisco VG204 voice gateways are installed on a wall, there should be plenty of space on both sides to ensure that there is adequate airflow through the chassis. OL-15959-01 Cisco VG202 and Cisco VG204 Voice Gateways Hardware Installation Guide 2-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

CHAPTER
2-1
Cisco VG202 and Cisco VG204 Voice Gateways Hardware Installation Guide
OL-15959-01
2
Planning Your Installation
Before you install your Cisco VG202 and Cisco VG204 voice gateways, consider the information in this
chapter:
Location and Mounting Requirements, page 2-1
Distance Limitations for Interface Cables, page 2-2
Interference Considerations, page 2-3
Location and Mounting Requirements
There are two ways of mounting the Cisco VG202 and Cisco VG204 voice gateways:
Wall mounting
Desktop mounting
Whether wall or desktop, the mounting location must provide the following:
Access to the chassis
Access to a suitable power source
Access to an appropriate earth ground
Allowance for adequate heat dissipation and airflow around the chassis
Temperature Control and Ventilation
The installation area (room, closet, or cabinet) for the Cisco VG202 and Cisco VG204 voice gateways
should always be well ventilated and should provide adequate air circulation to ensure proper cooling.
The room temperature should be maintained from 32 to 122°F (0 to 50°C).
Wall Mounting
If the Cisco VG202 and Cisco VG204 voice gateways are installed on a wall, there should be plenty of
space on both sides to ensure that there is adequate airflow through the chassis.