Compaq BL10e HP ProLiant BL e-Class System Setup and Installation Guide - Page 115
Table D-8, Is the Fan Health LED Green
UPC - 613326445501
View all Compaq BL10e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
Troubleshooting Table D-8: Is the Fan Health LED Green? Answer No, it is off. No, it is red. Possible Reasons The fan cable or connectors are not properly connected. The Integrated Administrator module is not properly seated. At least two fans have failed or are not properly seated. You no longer have adequate cooling. Possible Solutions Be sure that the connectors on the fan cable are properly seated and not damaged. Contact HP or an authorized service provider for parts and service. Open the fan cage and look for amber LEDs to determine which fans have failed. Replace all failed fans. Contact HP or an authorized service provider for parts and service. No, it is amber. Yes, it is green. At least one redundant fan has failed. The system still has adequate cooling, but is no longer redundant. All fans are functional. Contact HP or an authorized service provider for parts and service. Check the local or remote console for error messages. Go to table D-6. If these steps have not identified the problem, contact HP or an authorized service provider for assistance. HP ProLiant BL e-Class System Setup and Installation Guide D-13