Compaq ProLiant 8500 Compaq ProLiant 8500 I/O Module Upgrade Guide - Page 37
Removing Cable Segment C, the top of the levers downward
View all Compaq ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Compaq ProLiant 8500 Server I/O Module Upgrade Guide 33 Removing Cable Segment C Cable segment C of the virtual power button cable is situated in the I/O module and connects to cable segment B located in the system midplane. Viewing the server from the rear, slide the I/O module backward several inches by following these steps: 1. Push in on the sides of the cam levers on the I/O module and rotate the top of the levers downward . 2. Pull the I/O module out of the chassis to gain access to the system midplane. 1 2 3 Figure 30. Gaining access to the I/O module 3. Open the air baffle.
Compaq ProLiant 8500 Server I/O Module Upgrade Guide
33
Removing Cable Segment C
Cable segment C of the virtual power button cable is situated in the I/O
module and connects to cable segment B located in the system midplane.
Viewing the server from the rear
,
slide the I/O module backward several
inches by following these steps:
1.
Push in on the sides of the cam levers
on the I/O module and rotate
the top of the levers downward
.
2.
Pull the I/O module out of the chassis
to gain access to the system
midplane.
3
1
2
Figure 30.
Gaining access to the I/O module
3.
Open the air baffle.