Dacor ERD30 Installation Instruction - Epicure Range - Page 10
Electrical Connection of ERD Series Ranges, continued
View all Dacor ERD30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Installation Instructions Electrical Connection of ERD Series Ranges (continued) Connecting to a Three-Wire Electrical System (where local codes permit) Cable from power supply WARNING Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. 1. Make sure power to the junction box is switched off at the circuit breaker or fuse box. 2. Connect the green and white appliance wires to the neutral (white) supply wire in the junction box. 3. Connect the black appliance wire to the black (L1) power supply wire in the junction box. 4. Connect the red appliance wire to the red (L2) power supply wire in the junction box. RED RED GREEN WHITE WHITE BLACK BLACK Junction box Wire nut (3 places) Conduit from appliance Connecting the Appliance to a Three-Wire Power Supply (where local codes permit) Connecting to a Four-Wire Electrical System with External Ground (where local codes permit) WARNING Do not ground the appliance to a gas supply pipe or hot water pipe. A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a length of No. 4 copper wire securely clamped to bare metal at both ends. 1. Make sure power to the junction box is switched off at the circuit breaker or fuse box. 2. Separate the green and white appliance wires. 3. Connect the white appliance wire to the neutral (white) supply wire in the junction box. 4. Connect the black appliance wire to the black (L1) power supply wire in the junction box. 5. Connect the red appliance wire to the red (L2) power supply wire in the junction box. 6. Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe. If connecting to a grounded cold water pipe, a separate copper grounding wire (No. 10 minimum) must be connected to a grounded cold water pipe by means of a clamp and then to an external grounding connector screw. Cable from power supply RED RED GREEN GREEN WHITE WHITE BLACK BLACK Junction box Wire nut (4 places) Separate No. 10 (minimum) copper grounding wire No. 4 copper wire Meter Clamp must be tight on pipe Metal water pipe Clamps Bare metal Conduit from appliance Connecting the Appliance Ground to a Grounded Junction Box Wire or Grounded Cold Water Pipe 8