Installation Instructions Utility Locations 6" (152mm) Backguard 30" (762mm) 6" (152mm) Backguard 60" (1524mm) Power Cord Factory installed 3/4" regulator (1/2" supply ok) Gas and Electrical Locations - 30 Inch Models Power Cord Factory installed 3/4" regulator (1/2" supply ok) Gas and Electrical Locations - 60 Inch Models Electrical Connection WARNING • On ERD series models connect the ground terminal (or lead) on the appliance to a grounded, metallic, permanent wiring system or grounding conductor. • ERG series models must be connected to a 3-prong grounded electrical outlet. Failure to do so may result in an electrical shock hazard. • Do not use an extension cord with this appliance. Such use may result in fire, electrical shock, or other personal injury. • Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electrical shock hazard. IMPORTANT: • The power supply must be properly polarized. Reverse polarity will result in continuous sparking of the electrodes, even after flame ignition. If there is any doubt as to whether the power supply is properly polarized or grounded, have it checked by a qualified electrician. • Two separate electrical circuits and gas supplies are required for the ERD60. See page 3 for electrical specifications. Electrical Connection of EGR Series Ranges Connect ERG series models to a 3-prong grounded electrical outlet. Electrical Connection of ERD Series Ranges With the range positioned directly in front of the cabinet cutout, feed the appliance conduit(s) to the electrical junction box. Then, depending upon local codes, utilize either one of the following three techniques to connect the appliance to the electrical power supply: Four Wire Method (see column 2 on this page) Three Wire Neutral Ground Method (See page 8) Four Wire Method with External Ground (See page 8) Connecting to a Four-Wire Electrical System 1. Make sure power to the junction box is switched off at the circuit breaker or fuse box. 2. Separate the green and white appliance wires. 3. Connect the white appliance wire to the neutral (white) supply wire in the junction box. 4. Connect the black appliance wire to the black (L1) power supply wire in the junction box. 5. Connect the red appliance wire to the red (L2) power supply wire in the junction box. 6. Connect the green appliance wire to the green house grounding wire in the junction box. Cable from power supply Junction box RED RED GREEN GREEN WHITE WHITE BLACK BLACK Wire nut (4 places) Conduit from appliance Connecting the Appliance to a Four-Wire Power Supply 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

7
Installation Instructions
Utility Locations
Power Cord
30” (762mm)
Factory installed
3/4” regulator (1/2” supply ok)
6" (152mm)
Backguard
Power Cord
60” (1524mm)
Factory installed 3/4” regulator (1/2” supply ok)
6" (152mm)
Backguard
Electrical Connection
WARNING
On ERD series models connect the ground terminal (or
lead) on the appliance to a grounded, metallic, permanent
wiring system or grounding conductor.
ERG series models must be connected to a 3-prong
grounded electrical outlet. Failure to do so may result in an
electrical shock hazard.
Do not use an extension cord with this appliance. Such use
may result in fire, electrical shock, or other personal injury.
Do not install a fuse in the neutral or ground circuit. A fuse
in the neutral or ground circuit may result in an electrical
shock hazard.
IMPORTANT
:
The power supply must be properly polarized. Reverse
polarity will result in continuous sparking of the electrodes,
even after flame ignition. If there is any doubt as to whether
the power supply is properly polarized or grounded, have it
checked by a qualified electrician.
Two separate electrical circuits and gas supplies are required
for the ERD60. See page 3 for electrical specifications.
Electrical Connection of EGR Series Ranges
Connect ERG series models to a 3-prong grounded electrical
outlet.
Electrical Connection of ERD Series Ranges
With the range positioned directly in front of the cabinet cutout,
feed the appliance conduit(s) to the electrical junction box. Then,
depending upon local codes, utilize either one of the following
three techniques to connect the appliance to the electrical power
supply:
Four Wire Method (see column 2 on this page)
Three Wire Neutral Ground Method (See page 8)
Four Wire Method with External Ground (See page 8)
Gas and Electrical Locations - 30 Inch Models
Gas and Electrical Locations - 60 Inch Models
Connecting to a Four-Wire Electrical System
Make sure power to the junction box is switched off at the
1.
circuit breaker or fuse box.
Separate the green and white appliance wires.
2.
Connect the white appliance wire to the neutral (white) supply
3.
wire in the junction box.
Connect the black appliance wire to the black (L1) power
4.
supply wire in the junction box.
Connect the red appliance wire to the red (L2) power supply
5.
wire in the junction box.
Connect the green appliance wire to the green house
6.
grounding wire in the junction box.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Connecting the Appliance to a