Dacor ERD30 Installation Instruction - Epicure Range - Page 11

Gas Connection, Installing the Range

Page 11 highlights

Installation Instructions Gas Connection WARNING • Make sure the gas is turned off at the gas supply valve before connecting the gas line. • Do not apply excessive pressure when tightening gas connections and fittings. • Do not use teflon tape or plumber's putty on gas flex line connections. • Turn all cooktop control valves to the OFF position. Turn on gas supply and check all lines and connections for leaks using a soap and water solution. Do not use a flame to check for leaks. After verifying that there are no gas leaks, turn off the gas supply to the range by turning the gas shutoff valve to the OFF position. • For LP installations, the LP gas tank must have its own high pressure regulator. This is in addition to the pressure regulator provided with the range. • The maximum gas supply pressure to the range gas regulator must never exceed 1/2 pound per square inch. IMPORTANT: The gas pressure regulator is pre-set at the factory for the type of gas intended for use with the appliance. Verify that the appliance is compatible with the type of gas available by checking the data plate located behind the inlet air cooling grill. Open the oven door and remove the inlet air cooling grill for access to the data plate. Ranges intended for use with LP gases will have "LP" as a part of the model number. Consult your dealer if the range is not compatible with your gas supply. Gas Line Installation Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off valve previously installed on the stub out. The gas valve must be turned off during installation. Connect the flex connector to the pipe fitting at the rear of the range. Installing the Range Installation of Self-Rimming Configuration (Models ERD30 and EGR30 only) 1. Measure the distance from the floor to the countertop. Adjust the leveling legs to position the bottom edge of the range top frame approximately 1/8" above the level of the countertop to allow the range to slide over it. 2. Attach the anti-tip leveler to the range as shown below, if it is not already attached. Lower the ant-tip leveler until it is 3/16" off the floor so that it will engage the anti-tip bracket when the range is pushed into its final position. 3. Carefully slide the range into position in the cutout. The rear anti-tip leg should engage the anti-tip bracket. 4. Lower the range onto the countertop by turning the leveling legs counterclockwise. Lower the range until the bottom of the range top just contacts the countertop. Do not allow the full weight of the range to hang on the counter. Installation of Free-Standing Configurations 1. Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation. 2. On models ERD30 and EGR30, attach the anti-tip leveler to the range as shown below if it is not already attached. Lower the ant-tip leveler until it is 1/16" off the floor so that it will engage the anti-tip bracket when the range is pushed into its final position. 3. Carefully slide the range into position in the cutout. On models ERD30 and EGR30, the rear anti-tip leg should engage the anti-tip bracket. Rear Leveler 5/16 - 18 x 2 or Equivalent Left Rear Leg Location Anti-Tip Leveler (Models ERD30 and EGR30 Only) 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

9
Installation Instructions
Gas Connection
WARNING
Make sure the gas is turned off at the gas supply valve
before connecting the gas line.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use teflon tape or plumber’s putty on gas flex line
connections.
Turn all cooktop control valves to the
OFF
position. Turn on
gas supply and check all lines and connections for leaks
using a soap and water solution. Do not use a flame to
check for leaks. After verifying that there are no gas leaks,
turn off the gas supply to the range by turning the gas shut-
off valve to the
OFF
position.
For LP installations, the LP gas tank must have its own
high pressure regulator. This is in addition to the pressure
regulator provided with the range.
The maximum gas supply pressure to the range gas
regulator must never exceed 1/2 pound per square inch.
IMPORTANT:
The gas pressure regulator is pre-set at the factory
for the type of gas intended for use with the appliance. Verify
that the appliance is compatible with the type of gas available
by checking the data plate located behind the inlet air cooling
grill. Open the oven door and remove the inlet air cooling grill for
access to the data plate. Ranges intended for use with LP gases
will have “LP” as a part of the model number. Consult your dealer
if the range is not compatible with your gas supply.
Gas Line Installation
Before sliding the range into the cabinet, connect a flexible gas
connector to the gas shut-off valve previously installed on the stub
out. The gas valve must be turned off during installation. Connect
the flex connector to the pipe fitting at the rear of the range.
Installing the Range
Installation of Self-Rimming Configuration
(Models ERD30 and EGR30 only)
Measure the distance from the floor to the countertop. Adjust
1.
the leveling legs to position the bottom edge of the range top
frame approximately 1/8” above the level of the countertop to
allow the range to slide over it.
Attach the anti-tip leveler to the range as shown below, if it is
2.
not already attached. Lower the ant-tip leveler until it is 3/16”
off the floor so that it will engage the anti-tip bracket when the
range is pushed into its final position.
Carefully slide the range into position in the cutout. The rear
3.
anti-tip leg should engage the anti-tip bracket.
Lower the range onto the countertop by turning the leveling
4.
legs counterclockwise. Lower the range until the bottom of
the range top just contacts the countertop. Do not allow the
full weight of the range to hang on the counter.
Installation of Free-Standing Configurations
Measure from the floor to the countertop and adjust the
1.
leveling legs as required to position the top frame at
the desired height based on the cabinet and countertop
installation.
On models ERD30 and EGR30, attach the anti-tip leveler to
2.
the range as shown below if it is not already attached. Lower
the ant-tip leveler until it is 1/16” off the floor so that it will
engage the anti-tip bracket when the range is pushed into its
final position.
Carefully slide the range into position in the cutout. On
3.
models ERD30 and EGR30, the rear anti-tip leg should
engage the anti-tip bracket.
Left
Rear
Leg
Leveler
5/16 - 18 x 2
or Equivalent
Rear
Location Anti-Tip Leveler (Models ERD30 and EGR30 Only)