Dell C1048P Port Extender Networking C1048P Getting Started Guide - Page 8

SFP+ ACT right LED, SFP+ LNK left LED

Page 8 highlights

LED Status Fan MPS Stack Master/ Member SFP+ LNK (left LED above port) SFP+ ACT (right LED above port) Description • Off: Error condition - There is no power reaching the PE or the PE has a power failure. System operational status • Solid green: Normal operation • Blinking green: The PE is booting. • Solid red: Critical system error • Blinking red: Non-critical system error, such as a fan or power supply failure • Solid green: The fan is powered on and is operating at normal RPM speed. • Solid red: Fan failure Modular power supply (MPS) status (redundant external power supply) • Off: No external (modular) power supply is used. • Solid green: The PE is receiving power. • Solid red: An external power supply is detected, but is not receiving power. Stack master status • Off: The PE is operating as a stack member. • Solid green: The PE is operating as a stack master or in standalone mode. NOTE: While the C1048P is booting up in standalone or stacking mode, the Stack Master LED is solid green. SFP+ link status • Off: No data link • Solid green: Link is up and operating at maximum 10G port speed. • Solid amber: Link is up and operating at lower 1G port speed. SFP+ activity status • Off: No data link activity • Flashing green: Link is up and transmitting/receiving data. 8 C1048P Hardware Description

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

LED
Description
Off: Error condition — There is no power reaching the PE or the PE has a
power failure.
Status
System operational status
Solid green: Normal operation
Blinking green: The PE is booting.
Solid red: Critical system error
Blinking red: Non-critical system error, such as a fan or power supply failure
Fan
Solid green: The fan is powered on and is operating at normal RPM speed.
Solid red: Fan failure
MPS
Modular power supply (MPS) status (redundant external power supply)
Off: No external (modular) power supply is used.
Solid green: The PE is receiving power.
Solid red: An external power supply is detected, but is not receiving power.
Stack Master/
Member
Stack master status
Off: The PE is operating as a stack member.
Solid green: The PE is operating as a stack master or in standalone mode.
NOTE:
While the C1048P is booting up in standalone or stacking
mode, the Stack Master LED is solid green.
SFP+ LNK (left LED
above port)
SFP+ link status
Off: No data link
Solid green: Link is up and operating at maximum 10G port speed.
Solid amber: Link is up and operating at lower 1G port speed.
SFP+ ACT (right LED
above port)
SFP+ activity status
Off: No data link activity
Flashing green: Link is up and transmitting/receiving data.
8