Revision1.40 Date 24.May.'07 2.6 Command specification DCM390 Serial Interface Specification 13 page of 40 2.6.1 RESET command This command resets the device. After RESET command the device will do some operations for reset and return Answer code. At last the device resets itself. 1) Command format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Command code ('SP') 2 Reserve (0x00) 3 Reserve (0x00) 4 Reserve (0x00) 5 Reserve (0x00) 6 ETX (0x03) 7 BCCH (high-level) 8 BCCL (low-level) Table 5. Reset command 2) Answer format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Reply code ('SP') 2 Answer code (Table 3) 3 ETX (0x03) 4 BCCH (high-level) 5 BCCL (low-level) Table 6. Reset answer 3) Special condition This device cannot receive any commands within 2 seconds after this command is sent. After Reset command, the host shall wait the device becomes ready status. The device returns not Ready status for Request Status command before get ready. D&M