Denon DCM 390 Serial Protocol - Page 24
Answer format, Table 31. Request Text Data answer, Special conditions
UPC - 081757506991
View all Denon DCM 390 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Revision1.40 Date 24.May.'07 DCM390 Serial Interface Specification 24 page of 40 2) Answer format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Reply code ('6') 2 Answer code (Table 3) 3 Data Type (Table 29) 4 Track number 100 digits (Table 30) 5 Track number 10 digits (Table 30) 6 Track number 1 digits (Table 30) 7-36 Text Data (30charactors) 37 ETX (0x03) 38 BCCH (high-level) 39 BCCL (low-level) Table 31. Request Text Data answer 3) Special conditions - If Text Data 30Characters or more , then put in 30Charactors . - If Text Data 29Characters or less ,then put in null(0x00) after the last character. D&M
Revision1.40
DCM390 Serial Interface Specification
Date 24.May.’07
24 page of 40
2) Answer format
Byte/bit
7
6
5
4
3
2
1
0
0
STX (0x02)
1
Reply code (‘6’)
2
Answer code (Table 3)
3
Data Type (Table 29)
4
Track number 100 digits (Table 30)
5
Track number 10 digits (Table 30)
6
Track number
1 digits (Table 30)
7-36
Text Data (30charactors)
37
ETX (0x03)
38
BCCH (high-level)
39
BCCL (low-level)
Table 31. Request Text Data answer
3) Special conditions
- If Text Data 30Characters or more , then put in 30Charactors .
- If Text Data 29Characters or less ,then put in null(0x00) after the last character.