Denon DCM 390 Serial Protocol - Page 30

Open / Close Command, Command format, Table 43. Open / Close command, Answer format, Table 44.

Page 30 highlights

Revision1.40 Date 24.May.'07 DCM390 Serial Interface Specification 30 page of 40 2.6.12 Open / Close Command This command opens and closes the loader of the CD. 1) Command format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Command code ('E') 2 Open / Close Code (Close: '0', Open: '1') 3 Reserve (0x00) 4 Reserve (0x00) 5 Reserve (0x00) 6 ETX (0x03) 7 BCCH (high-level) 8 BCCL (low-level) Table 43. Open / Close command 2) Answer format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Reply code ('E') 2 Answer code (Table 3) 3 ETX (0x03) 4 BCCH (high-level) 5 BCCL (low-level) Table 44. Open / Close answer 3) Special condition D&M

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Revision1.40
DCM390 Serial Interface Specification
Date 24.May.’07
30 page of 40
2.6.12 Open / Close Command
This command opens and closes the loader of the CD.
1) Command format
Byte/bit
7
6
5
4
3
2
1
0
0
STX (0x02)
1
Command code (‘E’)
2
Open / Close Code (Close: ‘0’, Open: ‘1’)
3
Reserve (0x00)
4
Reserve (0x00)
5
Reserve (0x00)
6
ETX (0x03)
7
BCCH (high-level)
8
BCCL (low-level)
Table 43. Open / Close command
2) Answer format
Byte/bit
7
6
5
4
3
2
1
0
0
STX (0x02)
1
Reply code (‘E’)
2
Answer code (Table 3)
3
ETX (0x03)
4
BCCH (high-level)
5
BCCL (low-level)
Table 44. Open / Close answer
3) Special condition