Page 31 highlights
Revision1.40 Date 24.May.'07 DCM390 Serial Interface Specification 31 page of 40 2.6.13 Program / Direct command This command selects a program mode or a direct mode. (CD) 1) Command format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Command code ('F') 2 Program / Direct Code (Direct: '0', Program: '1') 3 Reserve (0x00) 4 Reserve (0x00) 5 Reserve (0x00) 6 ETX (0x03) 7 BCCH (high-level) 8 BCCL (low-level) Table 45. Program / Direct command 2) Answer format Byte/bit 7 6 5 4 3 2 1 0 0 STX (0x02) 1 Reply code ('F') 2 Answer code (Table 3) 3 ETX (0x03) 4 BCCH (high-level) 5 BCCL (low-level) Table 46. Program / Direct answer 3) Special condition This command receives it only when it stops. If you need program clear, select a direct mode. D&M
Revision1.40
DCM390 Serial Interface Specification
Date 24.May.’07
31 page of 40
2.6.13 Program / Direct command
This command selects a program mode or a direct mode. (CD)
1) Command format
Byte/bit
7
6
5
4
3
2
1
0
0
STX (0x02)
1
Command code (‘F’)
2
Program / Direct Code (Direct: ‘0’, Program: ‘1’)
3
Reserve (0x00)
4
Reserve (0x00)
5
Reserve (0x00)
6
ETX (0x03)
7
BCCH (high-level)
8
BCCL (low-level)
Table 45. Program / Direct command
2) Answer format
Byte/bit
7
6
5
4
3
2
1
0
0
STX (0x02)
1
Reply code (‘F’)
2
Answer code (Table 3)
3
ETX (0x03)
4
BCCH (high-level)
5
BCCL (low-level)
Table 46. Program / Direct answer
3) Special condition
This command receives it only when it stops.
If you need program clear, select a direct mode.