Epson 4000 Service Manual - Page 341
Motor Assy., PF
UPC - 010343848337
View all Epson 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 341 highlights
EPSON Stylus Pro 4000 4.2.9.3 Motor Assy., PF 1. Remove "Cover, Side, Left" (p211). 2. Disconnect "Motor Assy., PF" harness (CN14: black, 2 pin) from "C511 MAIN Board" and peel off the acetate tape to release the harnesses. (Refer to "4.2.4.1 C511 MAIN Board" (p221).) 3. Release "Motor Assy., PF" harness and other harnesses from the two tabs and the three grooves on "Paper Guide, Lower". (Refer to Figure 4-206.) 4. Peel off the pieces of acetate tape to release "Motor Assy., PF" harness and then pull it through the hole in the frame. (Refer to Figure 4-207.) 5. Remove the two screws securing the "Guide, FFC" and then lower the "Guide, FFC" along with all FFCs. (Refer to Figure 4-208.) C.B.S. 3x6 C.B. 3x4 : 1 pc. : 1 pcs. Align the dowel of the frame with "Guide, FFC" positioning hole. (Refer to Figure 4-208.) Revision B Motor Assy., PF Acetate Tape (x3) Figure 4-207. Releasing the Harness_2 Guide, FFC FFC Harness Tabs Paper Guide, Lower C.B. 3x4 Channels Figure 4-206. Releasing the Harness_1 Dowels and Positioning Holes C.B.S 3x6 Figure 4-208. Releasing Guide, FFC Disassembly & Assembly Disassembly Procedures 341