Epson 4000 Service Manual - Page 372
Multi Sensor Position Adjustment
UPC - 010343848337
View all Epson 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 372 highlights
EPSON Stylus Pro 4000 5.2.6 Multi Sensor Position Adjustment This adjustment sets a suitable distance between the Multi Sensor (Multi Sensor Holder) and the platen. Required Tools Multi Sensor Position Tool CR Lock Tool Procedure 1. Turn the "Bushing, Shaft, Rear" so that [Lever, Lock, PG] goes into the furthest right notch of "Bushing, Shaft, Rear". 2. Place position tool 3.0 on "Paper Guide Assy., Paper Eject, Front, Right" at the position shown by Figure 5-15. 3. Move the Carriage Unit to the position where the "Multi Sensor Holder" touches the position tool. C A U T IO N When moving the Carriage Unit, do not let the Print Head contact the thickness gauge. Position Tool Carriage Unit Printhead Lever, Lock, PG Revision B Bushing, Shaft, Rear Figure 5-14. Multi Sensor Position Adjustment_1 Paper Guide Assy., Paper Eject, Front, Right Position Tool Figure 5-15. Setting the Position Tool Adjustment Mechanical Adjustment 372