Drill diameter, 8 inch anchor bolts: 0.39 in. 10 mm, Pilot hole depth, 8 in. 45 mm
View all Epson BrightLink EB-735Fi manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
2. Drive an M10 screw (not included) into the temporary wall plate hole. Leave at least 0.2 inch (6 mm) between the screw head and the wall. 3. Determine the position of the wall plate's mounting holes. Use at least four mounting holes for proper balance. 4. Drill holes of the following diameters and depths. Drill diameter Pilot hole depth Anchor hole depth 3/8 inch anchor bolts: 0.39 in. (10 mm) M10 anchor bolts: 0.41 in. (10.5 mm) 1.8 in. (45 mm) 1.6 in. (40 mm) 5. Remove the template sheet. 6. If necessary, use a device such as a dust pump to clean out concrete dust from the hole. 46
46
2.
Drive an M10 screw (not included) into the temporary wall plate hole.
Leave at least 0.2 inch (6 mm) between the screw head and the wall.
3.
Determine the position of the wall plate’s mounting holes.
Use at least four mounting holes for proper balance.
4.
Drill holes of the following diameters and depths.
5.
Remove the template sheet.
6.
If necessary, use a device such as a dust pump to clean out concrete dust from the hole.
Drill diameter
3/8 inch anchor bolts: 0.39 in. (10 mm)
M10 anchor bolts: 0.41 in. (10.5 mm)
Pilot hole depth
1.8 in. (45 mm)
Anchor hole depth
1.6 in. (40 mm)