    DOUBLE DISHDRAWER™ DISHWASHER DD24DDFT & DD24DV2T models INSTALLATION GUIDE US CA 591385C 05.19
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 2
    dishwasher MUST be installed to allow for future removal from the enclosure if service is required. O The switched power outlet must be outside the dishwasher in injury or cuts. IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 3
    2 PARTS SUPPLIED Drain hose support (1) Drain hose joiner (1) Wire clip (2) (for securing Drain hose joiner) Clamp to be used as a guide on how to install a DishDrawer™ yourself. https://vimeo.com/325297597 If the Drain hoses supplied are not long enough to reach your services, you must use a
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 4
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-A REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 3-B REMOVE THE ACCESS COVER & REMOVE POWER CORD 3 3 1 2 4" (
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 5
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS 12 8 9 13 14 11 IMPORTANT! Ensure the mains wires are routed UNDERNEATH all other harness 10 wiring from the electronics module. 8 Fit a suitable cable clamp for the conduit
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 6
    Handles may vary H K I FRONT B J G D E O PLAN 5 4 PRODUCT DIMENSIONS C A F L PROFILE M N PRODUCT DIMENSIONS A Overall height of product 1 B Overall width of product C Overall depth of product (excl. handle) D Depth of chassis (to back of front drawer panel) E Depth of drawer front panel (
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 7
    5 CABINETRY DIMENSIONS l m Bracket slots PLAN CABINETRY DIMENSIONS P Inside height of cavity* Q Inside width of cavity R Inside depth of cavity S Recommended height of adjacent cabinet space T Height of toekick space* * depending on adjustment of leveling feet DD24DDFT DD24DV2T INCHES (MM)
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 8
    (10mm) Max distance between hole edge and floor Service Holes Can be located either side of dishwasher, close to the rear face and the floor, as male compression fitting. Water Pressure Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) Models without water softener Max. 1 MPa (145
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 9
    7 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hoses - 78 1/2" (2000mm) Inlet hose - 64 3/4" (1650mm) Power cord (excl.plug) - 29 1/2" (750mm) RIGHT HAND SIDE Drain hoses - 70 1/2" (1800mm) Inlet hose - 49" (1250mm) Power cord (excl.plug) - 27 1/2" (700mm) 8
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 10
    NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 8 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 8-A ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed B screwdriver.
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 11
    !0-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 2 Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 !1-A OPTIONALLY SECURE TO THE
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 12
    8 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL 8-B PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the two top mounting brackets (x2) When fitting brackets, ensure the ends are not pushed down into the chassis. Initially level the product You can raise or lower the product by
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 13
    !0-B SECURE TO THE CABINETRY ON THE SIDES For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand. !1-B OPTIONALLY SECURE TO THE CABINETRY ABOVE (x2) The top mounting brackets will only bend upwards a maximum
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 14
    !3 FIT THE SUPPLIED TOEKICK PANEL Where the toekick meets the bottom 3 of the tub is the cut-off point 1 Lay the toekick face down on a chopping board or similiar 2 Mark this point on the toekick with a pencil 4 19 Score along the marked cutoff line with a knife 5 19 Turn the toekick over
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 15
    AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 1 1/2" (38 mm) Standpipe Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain hose support 2 to required height. max. 4 3/4" (120 mm) 29 1/2"-34
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 16
    DRAINAGE OPTION 2 Dishwasher using Dual Air Gap/Break with Drain Hose Joiner IMPORTANT! We recommend the use of a commercially available Dual (Double) Air Gap/Break Kit. This provides totally separate draining for each drawer and eliminates possible "cross draining" problems Drain hose Drain hose
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 17
    mm) 29 1/2 - 34 3/4" (750-883 mm) DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain 2 hose support to required height. max. 4 3/4 " (120 mm) Supplied drain
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 18
    the drawer from closing properly eg hoses or drawer latches. O If a problem occurs, consult the 'Troubleshooting' section of the User guide. O If after checking these points you still need assistance, please refer to the Service & Warranty book for warranty details and your nearest Authorized
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 19
    parts are installed. Ensure that all panels and parts drain hose joiner must not support the weight of excess hose hose should be kept on the dishwasher side of the highloop. If softener models only: adjust the water softener the Quick start guide and section 'Water softener' in the User guide. Turn on
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 20
    SINGLE DISHDRAWER™ DISHWASHER DD24SDFT & DD24SV2T models INSTALLATION GUIDE US CA 591385C 05.19
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 21
    dishwasher MUST be installed to allow for future removal from the enclosure if service is required. O The switched power outlet must be outside the dishwasher in injury or cuts. IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this installation guide may not be available in all markets and
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 22
    2 PARTS SUPPLIED Drain hose support (1) Drain hose joiner (1) (supplied with Fisher & Paykel Tall Height Models only) Dishdrawer installation overview This video provides an as a guide on how to install a DishDrawer™ yourself. https://vimeo.com/325297597 Edge Protector (1) (If the services hole is
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 23
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-A REMOVE THE DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 3 4 Push drawer 2 runners back in on either side. Sit the drawer
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 24
    3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS 12 8 9 13 14 11 IMPORTANT! Ensure the mains wires are routed UNDERNEATH all other harness 10 wiring from the electronics module. 8 Fit a suitable cable clamp for the conduit
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 25
    Handles may vary H F FRONT I B D E j PLAN 5 4 PRODUCT DIMENSIONS C A G PROFILE PRODUCT DIMENSIONS A Overall height of product 1 B Overall width of product C Overall depth of product D Depth of chassis (to back of front drawer panel) E Depth of drawer front panel (excl. handle) F Height of
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 26
    CABINETRY DIMENSIONS K Inside height of cavity L Inside width of cavity M Inside depth of cavity 5 CABINETRY DIMENSIONS l m Bracket slots PLAN DD24SDFT INCHES (MM) 18 7/8" (480) 23 5/8" (600) min. 22 1/16" (560) DD24SV2T INCHES (MM) 17 15/16" (456) 24" (610) min. 22 1/16" (560) K PROFILE
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 27
    edge and shelf 7 Service Holes Can be located either side of dishwasher, close to the models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) Models without water softener Max. 1 MPa (145 psi) Min. 0.03 MPa (4.3 psi) IMPORTANT! The power outlet must be located in a cabinet adjacent to the dishwasher
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 28
    RIGHT HAND SIDE Drain hose - 70 1/2" (1800 mm) Inlet hose - 49" (1250 mm) Power cord (excl.plug) - 78 1/2" (2000 mm) 8 ATTACH CAVITY BRACKET (DD24SDFT MODELS ONLY) IMPORTANT! The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 29
    NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 9 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 9-A ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a B flat-bladed screwdriver.
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 30
    !1-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 31
    9 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL 9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY As you push product in, pull through hoses and cord, ensuring they don't get kinked or twisted. IMPORTANT! If product cannot be pushed in far enough, pull out again and rearrange hoses and cord. Do not
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 32
    !1-B SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. two pairs of formed brackets on either side of the chassis (use 5/8" (16mm) screws) 2 Before refitting the drawer, ensure the hoses are not twisted and
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 33
    OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 1 1/2" (38 mm) Standpipe Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain 2 hose support to required height. max. 4 3/4" (120mm) 29 1/2" - 34 3/4" (750
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 34
    DRAINAGE OPTION 2 Dishwasher using Air Gap/Break with Drain Hose Joiner Secure drain hose to drain hose joiner and secure to Air Gap/Break 2 IMPORTANT! Ensure that drain
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 35
    regulations. 15 29 1/2"- 34 3/4" (750 - 883mm) min. 19 11/16" (500mm) 29 1/2 - 34 3/4" (750 - 883mm) DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain hose
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 36
    !4 CONNECT INLET HOSE TO HOT WATER Ensure the supplied rubber washer is fitted inside the coupling. 1 180o No leaks! Tighten coupling with spanner. 2 !5 SWITCH PRODUCT ON 16
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 37
    the drawer from closing properly eg hoses or drawer latches. O If a problem occurs, consult the 'Troubleshooting' section of the User guide. O If after checking these points you still need assistance, please refer to the Service & Warranty book for warranty details and your nearest Authorized
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 38
    parts are installed. Ensure that all panels and parts drain hose joiner must not support the weight of excess hose hose should be kept on the dishwasher side of the highloop. If softener models only: adjust the water softener the Quick start guide and section 'Water softener' in the User guide. Turn on
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 39
    19
  • Fisher and Paykel DD24DCTX9 N | Installation Guide - Page 40
    20
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

591385C
05.19
INSTALLATION GUIDE
US CA
DOUBLE DISHDRAWER™ DISHWASHER
DD24DDFT & DD24DV2T
models