A C B A Electrical Plumbing C B F 3 1/2" (89 mm) 5/32" (4 mm) Frameless: Finish return, sides and top 10 5 CAVITY PREPARATION Recommended area above cavity for connections B Electrical Plumbing F F ! Floor 2 15/16" (75 mm) 4 11/32" (110 mm) 4 11/32" (110 mm) 5 29/32" (150 mm) 5 29/32" (150 mm) 5 3/32" (129 mm) Alternative electrical connection location REAR VIEW OF CAVITY 31 1/2" (800 mm) CAVITY DIMENSIONS A Overall height of cavity B Overall width of cavity (when adjoining cabinetry cannot share 5/32" (4 mm) door gap) ! C Overall depth of cavity inches (mm) 72" (1829) 36" (914) 25" (635) ELECTRICAL SPECIFICATIONS Supply Service RS36A72J 115VAC, 60 Hz 10 amp circuit RS36A72U 115VAC, 60 Hz 10 amp circuit PLUMBING SPECIFICATIONS Supply Pressure - 1/4" (6 mm) PEX hose or Copper tubing* - Minimum 22 psi (150 kPa) Maximum 120 psi (827 kPa) @ 20°C Note: recommended that the electrical and water connection be located above the fridge cavity. Optional to locate in an adjacent cabinet to either side of the fridge. Do not locate water or electricity in this area, keep clear of connections. L !! G CAUTION: central area can only fit electrical plug if it is placed within a recessed cavity. * W  ater fittings kit - The standard appliance does not include water fittings. Standard Fisher & Paykel water fittings kit are available (part number: 841301). These parts need to be purchased separately by the customer and comply with local regulations.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

10
A
C
B
!
5
CAVITY PREPARATION
Electrical
Plumbing
Electrical
Plumbing
Recommended area above
cavity for connections
CAVITY DIMENSIONS
inches (mm)
A
Overall height of cavity
72” (1829)
B
Overall width of cavity
(when adjoining cabinetry cannot share
·³´µ
” (4 mm) door gap)
36” (914)
C
Overall depth of cavity
25” (635)
Alternative electrical connection location
Floor
5 ±À³´µ”
(150 mm)
4 ¾¶µ”
(110 mm)
2 ¾·³»¼”
(75 mm)
5 ¿³´µ”
(129 mm)
5 ±À³´µ”
(150 mm)
31 º” (800 mm)
REAR VIEW OF CAVITY
RS36A72J
RS36A72U
ELECTRICAL SPECIFICATIONS
Supply
115VAC, 60 Hz
115VAC, 60 Hz
Service
10 amp circuit
10 amp circuit
PLUMBING SPECIFICATIONS
Supply
°” (6 mm) PEX hose or Copper tubing*
Pressure
Minimum 22 psi (150 kPa)
Maximum 120 psi (827 kPa) @ 20½C
Note: recommended that the electrical and water connection be located above the fridge cavity. Optional to locate
in an adjacent cabinet to either side of the fridge.
Do not locate water or electricity in this area, keep clear of connections.
CAUTION: central area can only fit electrical plug if it is placed within a recessed cavity.
* Water fittings kit – The standard appliance does not include water fittings. Standard Fisher & Paykel water fittings
kit are available (part number: 841301). These parts need to be purchased separately by the customer and comply