Error code Error code chart Fault condition Check E11 E13 E21 E25 E26 E31 E32 E35 E38 E41 E43 E45 E47 E48 E4A E52 E53 E54 E55 E57 E58 E59 E5A E5C E5D E5F E67 E68 E71 E91 E92 E93 E94 E97 E98 E9F EA1 EA2 EA3 EA5 EAE EF1 EF2 EF6 EF8 Fill time too long. Water leak in tub or air leak in air bell. Water not pumping out fast enough. Recirculation Pump Relay Sense Recirculation Pump Relay Electronic pressure switch failure. Pressure sensor calibration problem. Pressure sensor indicates water overfill. Air trap clogged. Control board thinks the door switch is open. Door PTC Circuit Problem Line door sensing failure. Door PTC Sensing Open Door PTC Sensing Closed Door PTC Sensing Problem Bad signal from tacho generator. Low Voltage to Motor Control Board. Over speed. Under speed. High current on inverter. High current on motor phase. No tacho signal for 3 seconds. High temperature on heat sink caused by overloading. High Voltage experienced by MC. Communication problem. MC is continuously resetting. Heater sensing relay failure. Current leakage to ground on heater or fuse opened. Drum water NTC failure. (Tub heater) Communication error between UI board and main control board. UI_MB communications error Console or Main Board control problem. Main Board control problem. Console or Main Board control problem. Console control problem. Communication protocol Power supply frequency out of limits Power supply voltage too high Power supply voltage too low Main Voltage sensing failure Line safe relay sensing failure Clogged drain pump. Too much soap. Control Reset Key Stuck Refer to test (1). Refer to test (2). Refer to test (3). Refer to Test (16) Refer to Test (16) Refer to test (4). Refer to test (4). Refer to test (5). Refer to test (5). Refer to test (6). Refer to Test (6) Refer to test (6). Refer to Test (6) Refer to Test (6) Refer to Test (6) Refer to test (7). Refer to test (15). Refer to test (9). Refer to test (9). Refer to test (8). Refer to test (8). Refer to test (9). Refer to test (8). Refer to test (12). Refer to test (10). Refer to test (10). Refer to test (13). Refer to test (13). Refer to test (14). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (10). Refer to test (10) Refer to test (12). Refer to test (12). Refer to test (12). Refer to test (12). Refer to test (12). Unclog the drain pump. Advise customer to reduce the amount of soap they are using. Refer to Test (17) Check all buttons 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Error code chart
Error
code
Fault condition
Check
E11
Fill time too long.
Refer to test (1).
E13
Water leak in tub or air leak in air bell.
Refer to test (2).
E21
Water not pumping out fast enough.
Refer to test (3).
E25
Recirculation Pump Relay Sense
Refer to Test (16)
E26
Recirculation Pump Relay
Refer to Test (16)
E31
Electronic pressure switch failure.
Refer to test (4).
E32
Pressure sensor calibration problem.
Refer to test (4).
E35
Pressure sensor indicates water overfill.
Refer to test (5).
E38
Air trap clogged.
Refer to test (5).
E41
Control board thinks the door switch is open.
Refer to test (6).
E43
Door PTC Circuit Problem
Refer to Test (6)
E45
Line door sensing failure.
Refer to test (6).
E47
Door PTC Sensing Open
Refer to Test (6)
E48
Door PTC Sensing Closed
Refer to Test (6)
E4A
Door PTC Sensing Problem
Refer to Test (6)
E52
Bad signal from tacho generator.
Refer to test (7).
E53
Low Voltage to Motor Control Board.
Refer to test (15).
E54
Over speed.
Refer to t
est (9).
E55
Under speed.
Refer to test (9).
E57
High current on inverter.
Refer to test (8).
E58
High current on motor phase.
Refer to test (8).
E59
No tacho signal for 3 seconds.
Refer to test (9).
E5A
High temperature on heat sink caused by overloading.
Refer to test (8).
E5C
High Voltage experienced by MC.
Refer to test (12).
E5D
Communication problem.
Refer to test (10).
E5F
MC is continuously resetting.
Refer to test (10).
E67
Heater sensing relay failure.
Refer to test (13).
E68
Current leakage to ground on heater or fuse opened.
Refer to test (13).
E71
Drum water NTC failure. (Tub heater)
Refer to test (14).
E91
Communication error between UI board and main control board.
Refer to test (11).
E92
UI_MB communications error
Refer to test (11).
E93
Console or Main Board control problem.
Refer to test (11).
E94
Main Board control problem.
Refer to test (11).
E97
Console or Main Board control problem.
Refer to test (11).
E98
Console control problem.
Refer to test (10).
E9F
Communication protocol
Refer to test (10)
EA1
Power supply frequency out of limits
Refer to test (12).
EA2
Power supply voltage too high
Refer to test (12).
EA3
Power supply voltage too low
Refer to test (12).
EA5
Main Voltage sensing failure
Refer to test (12).
EAE
Line safe relay sensing failure
Refer to test (12).
EF1
Clogged drain pump.
Unclog the drain pump.
EF2
Too much soap.
Advise customer to reduce the amount
of soap they are using.
EF6
Control Reset
Refer to Test (17)
EF8
Key Stuck
Check all buttons