Frigidaire FAFS4272LW Wiring Diagram (All Languages) - Page 3
Error code chart - problems
UPC - 012505382208
View all Frigidaire FAFS4272LW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Error code Error code chart Fault condition Check E11 E13 E21 E25 E26 E31 E32 E35 E38 E41 E43 E45 E47 E48 E4A E52 E53 E54 E55 E57 E58 E59 E5A E5C E5D E5F E67 E68 E71 E91 E92 E93 E94 E97 E98 E9F EA1 EA2 EA3 EA5 EAE EF1 EF2 EF6 EF8 Fill time too long. Water leak in tub or air leak in air bell. Water not pumping out fast enough. Recirculation Pump Relay Sense Recirculation Pump Relay Electronic pressure switch failure. Pressure sensor calibration problem. Pressure sensor indicates water overfill. Air trap clogged. Control board thinks the door switch is open. Door PTC Circuit Problem Line door sensing failure. Door PTC Sensing Open Door PTC Sensing Closed Door PTC Sensing Problem Bad signal from tacho generator. Low Voltage to Motor Control Board. Over speed. Under speed. High current on inverter. High current on motor phase. No tacho signal for 3 seconds. High temperature on heat sink caused by overloading. High Voltage experienced by MC. Communication problem. MC is continuously resetting. Heater sensing relay failure. Current leakage to ground on heater or fuse opened. Drum water NTC failure. (Tub heater) Communication error between UI board and main control board. UI_MB communications error Console or Main Board control problem. Main Board control problem. Console or Main Board control problem. Console control problem. Communication protocol Power supply frequency out of limits Power supply voltage too high Power supply voltage too low Main Voltage sensing failure Line safe relay sensing failure Clogged drain pump. Too much soap. Control Reset Key Stuck Refer to test (1). Refer to test (2). Refer to test (3). Refer to Test (16) Refer to Test (16) Refer to test (4). Refer to test (4). Refer to test (5). Refer to test (5). Refer to test (6). Refer to Test (6) Refer to test (6). Refer to Test (6) Refer to Test (6) Refer to Test (6) Refer to test (7). Refer to test (15). Refer to test (9). Refer to test (9). Refer to test (8). Refer to test (8). Refer to test (9). Refer to test (8). Refer to test (12). Refer to test (10). Refer to test (10). Refer to test (13). Refer to test (13). Refer to test (14). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (10). Refer to test (10) Refer to test (12). Refer to test (12). Refer to test (12). Refer to test (12). Refer to test (12). Unclog the drain pump. Advise customer to reduce the amount of soap they are using. Refer to Test (17) Check all buttons 3