Typical Gas Cooktop Installation Over, an Electric Built-in Oven Installed Under the Counter

Page 5 highlights

GAS COOKTOP INSTALLATION INSTRUCTIONS (For 30" & 36" Models) Typical Gas Cooktop Installation Over an Electric Built-in Oven Installed Under the Counter GAS COOKTOP Manifold Pipe Flexible Connector Cabinet sides or filler panel Wall Oven Cabinet 18" (45.7 cm) Max. 6½" 5" (16.5 cm) Flare (12.7 cm) Min. Union Flare Union Figure 4 4" (10.2 cm) 120V/60Hz Grounded Outlet Pressure Regulator Right Side of Cabinet Manual Shutoff Valve (To be accessible for shut-off valve opera- tion) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
5
Wall Oven Cabinet
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
GAS COOKTOP
18” (45.7 cm) Max.
5”
(12.7 cm)
Flare
Union
4” (10.2 cm)
120V/60Hz
Grounded
Outlet
Right Side
of Cabinet
Pressure
Regulator
Flare
Union
Flexible Connector
Cabinet sides or
filler panel
6½”
(16.5 cm)
Min.
Manifold Pipe
Manual Shutoff Valve
(To be accessible for
shut-off valve opera-
tion)