GAS COOKTOP INSTALLATION INSTRUCTIONS (For 30" & 36" Models) 1. Wall Outlet Location To clamp down, insert an angle bracket into the slot on each side of the unit as shown. Run thumb screw up through the bracket, up against the bottom of the counter. Tighten until the unit draws down and is secure. 3. Provide an Adequate Gas Supply This cooktop is designed to operate on natural gas at 4" of manifold pressure only. A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line. For proper operation, the maximum inlet pressure to the regulator must be no more than 14" of water column (W.C.) pressure. For checking the regulator, the inlet pressure must be at least 1" (or 2.5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" of manifold pressure, the inlet pressure must be at least 5". Figure 5 2. Cooktop Installation 1. Visually inspect the cooktop for damage. 2. Set the cooktop into the countertop cutout. After inserting the cooktop into the countertop opening, make sure the unit is sitting on the metal flange around the top of the burner box. Cooktop must not sit on the glass or the porcelain top. Avoid cutting an oversized hole in the countertop. NOTE: Do not use caulking compound; cooktop should be removable for service when needed. Clamp Down Information Once the cooktop is installed in the counter opening, you must clamp the unit down as shown. Cooktop (Glass or Porcelain) Seal (Porcelain Cooktop Only) Countertop Angle Bracket Thumb Screw The gas supply line to the range should be 1/2" or 3/4" pipe. 4. LP/Propane Gas Conversion This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with natural gas. A kit for converting to LP gas is supplied with your cooktop. The kit is marked "FOR LP/PROPANE GAS CONVERSION". The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. Failure to make the appropriate conversion can result in serious personal injury and property damage. Important: Remove all packing material and literature from cooktop before connecting gas and electrical supply to cooktop. Figure 6 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
6
To clamp down, insert an angle bracket into the slot
on each side of the unit as shown. Run thumb screw
up through the bracket, up against the bottom of the
counter. Tighten until the unit draws down and is secure.
3. Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4"
of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation,
the maximum inlet pressure
to the regulator must be no more than 14" of water
column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1" (or 2.5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be 1/2" or 3/4"
pipe.
4. LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANE GAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and
all local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate conversion
can result in serious personal injury and property
damage.
Important:
Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to cooktop.
1. Wall Outlet Location
Figure 5
2. Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
After inserting the cooktop into the countertop
opening, make sure the unit is sitting on the metal
flange around the top of the burner box. Cooktop
must not sit on the glass or the porcelain top. Avoid
cutting an oversized hole in the countertop.
NOTE:
Do not use caulking compound; cooktop should
be removable for service when needed.
Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
Figure 6
Countertop
Cooktop (Glass
or Porcelain)
Angle
Bracket
Seal (Porcelain
Cooktop Only)
Thumb
Screw