GE AJCS12DCC Owners Manual - Page 16

Window Installation—Optional on models so equipped, FOR MODELS AJES06LSC, AJES08ASC - dimensions

Page 16 highlights

Installation Instructions WINDOW INSTALLATION-OPTIONAL FOR MODELS AJES06LSC, AJES08ASC, AJES10DSC and AJHS08ASC Read these instructions completely and carefully. Sill support bracket (2) Case side gasket (2) Vinyl window gasket 2 angles (left and right hand) B Right side A Left side Filler Panels Cut panels and discard center piece Spring clip (4) Foam top window gasket Case top gasket Bottom window gasket Window locking bracket (holes are on the left) (holes are on the right) Air conditioner Support bracket hardware Type A (9) Type C (painted) (6) Type D (2) Type B (2) Type E (4) Spacer (2) Lock nut (2) Adjusting bolt (2) Large washer (2) 1 WINDOW REQUIREMENTS • These instructions are for a standard double-hung window. You will need to modify them for other types of windows. • The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right. • All supporting parts must be secured to firm wood, masonry or metal. • The electrical outlet must be within reach of the power cord. 16 17″ min. 31″ to 43″ (With filler panels) 261⁄4″ min. (Without filler panels) Window opening dimensions are for a standard double-hung window.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

Installation Instructions
16
WINDOW INSTALLATION—OPTIONAL
FOR MODELS AJES06LSC, AJES08ASC, AJES10DSC and AJHS08ASC
Read these instructions completely and carefully.
Air conditioner
Type C (painted) (6)
Type D (2)
Type E (4)
Large washer (2)
Adjusting bolt (2)
Lock nut (2)
Spacer (2)
Support bracket hardware
Type A (9)
Type B (2)
Sill support
bracket (2)
2 angles
(left and
right hand)
Case side
gasket (2)
Spring
clip (4)
Window
locking
bracket
Vinyl window
gasket
Bottom window gasket
Filler
Panels
Cut panels
and
discard
center
piece
Case top gasket
Foam top
window gasket
B
Right
side
A
Left side
(holes are on the left)
(holes are on the right)
WINDOW REQUIREMENTS
These instructions are for a standard double-hung
window. You will need to modify them for other
types of windows.
The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions
to the right.
All supporting parts must be secured to firm wood,
masonry or metal.
The electrical outlet must be within reach of the
power cord.
1
Window opening dimensions are for a
standard double-hung window.
17
min.
31
to 43
(With filler panels)
26
1
±
4
min.
(Without filler panels)