GE C2S980S Use and Care Manual - Page 47

Wire Power Cord Installation Option, Read these instructions completely and carefully.

Page 47 highlights

Safety Instructions Operating Instructions Read these instructions completely and carefully. Replace the Power Cord (Optional) Continued Perform this step only if the power cord shipped on the range does not match your wall receptacle. 3-Wire Power Cord Installation Option WARNING: The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. Locate the copper ground strap on the lower back of the range. Loosen the upper center screw on the terminal block. Slide the open slotted end of the ground strap under the upper center screw on the terminal block. Make sure the ground strap is all the way against the upper center screw and tighten it in place. Place the ground plate (removed earlier) over the bottom of the ground strap, press them against the range frame and attach them with the ground screw (removed earlier). Insert the new power cord through the strain relief. Allow enough slack to easily attach the wires to the terminal block. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely (approximately 20 inch-lbs.) into the terminal block. Secure the strain relief in place in the bracket by tightening the strain relief screws. Ground plate Power cord Ground strap Terminal block (appearance may vary) Neutral terminal Ground strap Open slotted end Installation Instructions Troubleshooting Tips Consumer Support 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

WARNING:
The neutral or ground
wire of the power cord must be connected to
the neutral terminal located in the center of
the terminal block. The power leads must be
connected to the lower left and the lower right
terminals of the terminal block.
Locate the copper ground strap on the
lower back of the range.
Loosen the upper center screw on the
terminal block.
Slide the open slotted end of the ground strap
under the upper center screw on the terminal
block. Make sure the ground strap is all the
way against the upper center screw and
tighten it in place.
Place the ground plate (removed earlier) over
the bottom of the ground strap, press them
against the range frame and attach them
with the ground screw (removed earlier).
Insert the new power cord through the strain
relief. Allow enough slack to easily attach the
wires to the terminal block.
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securely
(approximately 20 inch-lbs.) into the terminal
block.
Secure the strain relief in place in the bracket
by tightening the strain relief screws.
47
Read these instructions completely and carefully.
Ground strap
Terminal block
(appearance
may vary)
Neutral
terminal
Power cord
Ground
plate
Replace the Power Cord (Optional) Continued
Perform this step only if the power cord shipped on the range does not match your wall receptacle.
Ground strap
Open slotted end
3-Wire Power Cord Installation Option