GE PNM9196SFSS Installation Instructions - Page 20
Warning - model #
View all GE PNM9196SFSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation Instructions C3 ADAPTING BLOWER FOR RECIRCULATION NOTE: The exhaust adaptor with damper is not needed for recirculating models. You may want to save them for possible future use. 1 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. Blower Plate Blower Motor Screw 2 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. BEFORE: Fan Blade 2SHQLQJV)DFLQJ8S End B 4 Place the blower unit back into the opening. WARNING:5LVNRIHOHFWULFVKRFN can cause injury or death. Do not pull or stretch WKHEORZHUXQLWZLULQJ0DNHVXUHWKHZLUHGDUH not pinched. 5 Close the blower plate. Secure with the screw removed earlier. Blower Plate Back of Oven Screw End A 3 Roll the blower unit 90° so that fan blade openings are facing out the back of the oven. AFTER: Fan Blade 2SHQLQJV)DFLQJ Forward Back of Oven Back of Oven NOTE: Make sure wires remain routed in the grooves of the motor frame. 20