Chff^j\bZe Abj Chg]blbhg^j 9.5.3. Electric control function (For outdoor unit) A. Indoor unit A.1 Cooling operation A.1.1 Anti-freezed function of evaporator a. Be valid in cooling or defrost mode; be invalid in trial or heating mode. b. If the evaporator temperature is below -1 ℃ for 5 minutes, ourdoor fan and compressor will stop; if the evaporator temperature goes up to over 7℃ and the compressor has stopped for over 3 minutes, the unit will resume. c. When the evaporator anti-freezed function works, the indoor motor and the thermostor will work together. d. Compressor control Being powered on for the first time is without the 3-minutes protection. If the compressor stops, it can start up 3 minutes later. e. Remote controller control The adjustment of set temperature and the remote controller shutoff will not be limited by 6-minute control, you can shut off the unit right now. A.1.2 Dehumidification operation *temperature range:16~30℃ *temperature control precision:±1℃ *Control characteristic:Tr=room temperature; Ts=set temperature Tr>Ts+2℃,the compressor and the outdoor motor will go on running, the indoor motor will run at the set speed. T