Haier AB072XCEAA Service Manual - Page 75
When double units of different system are in cooling mode
View all Haier AB072XCEAA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Chff^j\bZe Abj Chg]blbhg^j contineously, then the outdoor stops running, and shows failure code. After the communication resumes normal operation and cancel the failure When all indoor units can not communicate normally, it shows communciation malfunction. A.2.4 Solenoid valve control with single unit in cooling mode If indoor unit sends the "start-compressor" signal, the corresponding solenoid valve will open; when shutting off the compressor, the corresponding solenoid valve will close. If the indoor units in one system all send the "stop-compressor" signal, the solenoid valve last receiving signal will close 3 minutes later. A.2.5 Solenoid valve control with single unit in heating mode If indoor unit sends the "start-compressor" signal, the corresponding two solenoid valves will open; if there is only one indoor unit, the two valves will open too. A.2.6 When double units of one system are in cooling mode, if the two indoor units send the "start-compressor" signal, the two solenoid valves will open; if one indoor sends "start-compressor" signal, while the other sends "stop-compressor", then the solenoid valve will open or close respectively. If the two units all send "stop-compressor" signal, the solenoid valve will open for 3 minutes after compressor stops. A.2.7 When double units of different system are in cooling mode, if the indoor unit sends the "start-compressor" signal, the corresponding solenoid valves will open; If the unit sends "stop-compressor" signal, the corresponding solenoid valve will open for 3 minutes after compressor stops. A.2.8 When double units of one system are in heating mode, if any of the two indoor units sends the "start-compressor" signal, the two solenoid valves will open. After compressor stops, the solenoid valve will close 3 minutes later. A.2.9 When double units of different system are in heating mode, if one indoor unit of one system sends the "start-compressor" signal, the two solenoid valves of this system will open. After compressor stops, the solenoid valve will close 3 minutes later. A.2.10 The treatment for 1 to 3 or 1 to 4 refers to the different combination of the above 1-7 items. A.2.11 Treatment for anti-freezed function When the two systems are in operation, if one system enters anti-freezed function, the compressor of this system will stop, while the outdoor motor and the other system will work normally. If the two systems all enter anti-freezed function, outdoor unit will stop operation, at this moment if one system resumes, outdoor motor and the corresponding system will work normally. The compressor of the system which does not resumes will stop. A.2.12 Treatment for overheating function The treatment of stop-compressor status is identical to that of anti-freezed status. If one system enters overheating 3, this system will stop, while the outdoor motor and the other system will work normally. If the two systems enter overheating 3, the outdoor will stop; at this moment if one system resumes, outdoor motor and the corresponding system will work normally. If the indoor units of the two systems all enter the overheating 2, outdoor motor will stop. The outdoor will not deal with the status of overheating 1. Note: The overheating point is decided by the indoor unit. z 73 z