Haier AB122ACERA Service Manual - Page 22

Floor Mounting, Under Ceiling Mounting

Page 22 highlights

Commercial Air Conditioner Model: AU122AEERA AB122ACERA AC122ACERA AD122ALERA 5.2.2 AC122ACERA INSTALLATION PROCEDURE Install the room air conditioning unit as follows: PREPARING INDOOR UNIT INSTALLATION FIRST REMOVE THE INTAKE GRILL A. FLOOR MOUNTING (AC36/42 only suitable for exposed ceiling mounting) 1. DRILLING FOR PIPING The piping and drain can exit the unit in two directions as shown below in (Fig. 2) rear Wrap the insulation around the drain hose connection.(Fig.6) (Fig. 6) Drain pan Drain hose Insulation (Drain hose) Be sure to arrange the drain hose correctly as shown in Fig. 7 so that it is lower than the drain hose connecting point of the indoor unit, if condensate pump is not fitted to system. Fig. 7 OK NO NO (Fig. 2) down The drain hose must be connected to the right side as shown in (Fig.3). (Fig. 3) Arrange the drain hose lower than this portion. Drain hose CAUTION! Ensure that the unit is fixed level. Height 'A' must be less than 5 mm.(Fig.8) Drain hose (Right side) After the piping and drainage exit has been selected, drill a 7 cm dia. hole through the wall so that the hole is slanting downward toward the outside to ensure good drainage. When the pipe is led out from the rear, make a hole as Fig.4, at the position shown. (Fig. 4) Wall 7cm Indoor unit 6mm outdoor unit 2. INSTALLING DRAIN HOSE The drain hose must be connected to the right side of the unit (Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener. (Fig.5) Drain hose A B. UNDER CEILING MOUNTING Using the installation template, drill holes for piping and anchor bolts(for holes).(Fig.9) (Fig. 10) 900mm 200mm Installation template Drilling position for anchor bolt Ceilling Wall Drilling position for piping (Fig. 5) Drain pan 1. DRILLING FOR PIPING Select piping and drain directions. (Fig.10) Drain hose Nylon fastener (supplied by others) Fig 10 Rear (Install the drain hose in this direction.) 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

CAUTION!
INSTALLATION PROCEDURE
Install the room air conditioning unit as follows:
PREPARING INDOOR UNIT INSTALLATION
FIRST REMOVE THE INTAKE GRILL
A.
FLOOR MOUNTING
(AC36/42 only suitable for
exposed ceiling mounting)
1.
DRILLING FOR PIPING
The piping and drain can exit the
unit in two directions as shown
below in (Fig. 2)
(Fig. 2)
The drain hose must be connected to the right side as
shown in (Fig.3).
After the piping and drainage exit has been selected,
drill a 7 cm dia. hole through the wall so that the
hole is slanting downward toward the outside to
ensure good drainage. When the pipe is led out from
the rear, make a hole as Fig.4, at the position shown.
2. INSTALLING DRAIN HOSE
The drain hose must be connected to the right side of
the unit (Fig.3)
Insert the drain hose into the drain pan, then secure
the drain hose with a nylon fastener. (Fig.5)
Be sure to arrange the drain hose correctly as shown
in Fig. 7 so that it is lower than the drain hose
connecting point of the indoor unit, if condensate
pump is not fitted to system.
B.
UNDER CEILING MOUNTING
Using the installation template, drill holes for piping
and anchor bolts(for holes).(Fig.9)
1. DRILLING FOR PIPING
Select piping and drain directions. (Fig.10)
Fig 10
(Fig. 6)
Drain pan
Drain hose
Insulation
(Drain hose)
Arrange the drain hose
lower than this portion.
Fig. 7
OK
NO
NO
Drain hose
rear
down
(Fig. 3)
Drain hose (Right side)
Wall
7cm
6mm
Indoor unit
outdoor unit
(Fig. 4)
Drain pan
Drain hose
Nylon fastener
(supplied by others)
(Fig. 5)
A
Drain hose
Rear (Install the drain hose
in this direction.)
Wrap the insulation around the drain hose
connection.(Fig.6)
Ensure that the unit is fixed level. Height
A
must be less
than 5 mm.(Fig.8)
Commercial Air Conditioner
Model: AU122AEERA AB122ACERA
AC122ACERA AD122ALERA
±²³´µ¶·¸¹
±²³´µ¶¶µ´·¸²
´¹º»¶µ´¹
¼µ¶¶
½¹·¶¶·²¾
¿À·¶¶·²¾Á»¸³·´·¸²
¸ÀÁ»·»·²¾
¿À·¶¶·²¾Á»¸³·´·¸²
¸ÀÁµ²ÃĸÀÁŸ¶´
ÆÇǺº
ÈÇǺº
5.2.2 AC122ACERA
22