Commercial Air Conditioner Model: AU122AEERA AB122ACERA AC122ACERA AD122ALERA WIRING DIAGRAM OF OUTDOOR UNIT 0150501661 52 LED1 LED2 ON LED3 1 2 3 4 LED4 LED5 LED BOARD AC FAN MOTOR CRANKCASE HEATER 6 4-WAY M Y/G 1 VALVE COMPRESSOR SUCTION SENSOR DEFROST TEMP.SENSOR AMBIENT TEMP. SENSOR COMPRESSOR DISCHARGE SENSOR CONDENSER INLET TEMP. SENSOR HIGH PRESSURE SWITCH 3 P LOW PRESSURE SWITCH P 4 CN5 CN6 CN7 CN10 CN8 CN17 CN18 CN16 CN11 P7 CN15 P6 SW1 SW3 7 CN12 CN13 FUSE101 T25A /250VAC SW2 SW4 MAIN BOARD CN3 P2 P3 P4 COM L N P6 P5 CN1 CN2 P1 Ground M 5 EEV NOTES: 1.DASHED PARTS 1 2 ARE JUST CAN SELECT ONE BETWEEN THIS TWO FAN MOTOR 2.PARTS IN DASHED FRAMES 3 4 5 6 ARE OPTIONAL 3. THE LED1-5 ON LED BOARD ARE USED FOR ERROR ALARM 4.PLEASE DO NOT PRESS SW1-4 IN DASHED FRAME 7 5.PLEASE DO NOT CHANG THE DIP SWITCH ON LED BOARD W BR 12 3 TO INDOOR UNIT CN5 CN3 SPDU U V M R R W S(W) W B C(T) P(OUT+) L(IN) N(IN) LX1 LX2 N(OUT-) P N COMPRESSOR R BL R BL REACTOR R CON24 CON21 BL CN20 CON22 CON23 2 CAPACITOR BOARD M DC FAN MOTOR Y/G Y/G W:WHITE B:BLACK R:RED OR:ORANGE BL:BLUE Y/G:YELLOW/GREEN TEMP.:TEMPERATURE AU122AEERA

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

Commercial Air Conditioner
REACTOR
CAPACITOR
BOARD
LX1
NOTES:
1.DASHED PARTS
ARE JUST CAN SELECT ONE BETWEEN
THIS TWO FAN MOTOR
2.PARTS IN DASHED FRAMES
ARE OPTIONAL
3. THE LED1-5 ON LED BOARD ARE USED FOR ERROR ALARM
4.PLEASE DO NOT PRESS SW1-4 IN DASHED
FRAME
5.PLEASE DO NOT CHANG THE DIP SWITCH ON LED BOARD
CONDENSER INLET TEMP. SENSOR
DEFROST TEMP.SENSOR
LOW PRESSURE
SWITCH
AMBIENT TEMP. SENSOR
HIGH PRESSURE
SWITCH
M
EEV
P
CN3
CN18
CN16
P
CN17
CN8
CN10
CN6
CN7
SW3
SW1
SW2
CN5
CN15
SW4
CN11
TO INDOOR UNIT
P6
P5
P2
P3
P1
N
L
COM
W
R
R
R
BL
BL
BL
R
B
P4
1
2
3
Ground
MAIN BOARD
CN13
CN1
CN12
Y/G
Y/G
WIRING DIAGRAM OF OUTDOOR UNIT
0150501661
4-WAY
VALVE
COMPRESSOR DISCHARGE SENSOR
COMPRESSOR SUCTION SENSOR
ON
LED BOARD
LED3
LED4
LED5
1
4
3
4
3
5
1
2
3
4
6
7
5
7
1
2
LED1
LED2
AC FAN MOTOR
DC FAN MOTOR
M
SPDU
L(IN)
N(IN)
CN5
B:BLACK
BL:BLUE
W:WHITE
R:RED
Y/G:YELLOW/GREEN
TEMP.:TEMPERATURE
CN2
Y/G
CN3
M
2
M
S(W)
V
COMPRESSOR
LX2
P
CON24
CON22
CN20
CON21
CON23
N
W
P(OUT+)
N(OUT-)
C(T)
U
R
OR:ORANGE
R
W
B
P6
P7
CRANKCASE
HEATER
6
T25A /250VAC
FUSE101
AU122AEERA
Model: AU122AEERA AB122ACERA
AC122ACERA AD122ALERA
52