Sleep Function

Page 13 highlights

Guide to Operation Sleep Function SET OFF AM AM MODE FAN SWING TEMP CLOCK TIMER SET SLEEP FILTER RESET RESET ON/OFF Before using this function, you should calibrate the clock first, otherwise, the SLEEP function will be out of order. Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep. Use of SLEEP function After unit start,first set running mode and then press SLEEP button once.Mark the air conditioner have the previous-set sleep time(first power-on or after carrying out sleep function is 1h),the sleep symbol will appear. Press time button / , you can choose the time in 1~8 hours.Each time the button is pressed the time increases/decreases 1 hour and ì xh î appears in the humidity setting part ,ì OFF î appears in ì TIMER OFF î display part. Press Sleep button again to cancel Sleep function and the sleep symbol disappears. Operation Mode 1.In COOL, DRY mode One hour after sleeping operation start, the temp. is 1 C higher than the setting one. After another hour the temp. rises 1 C and then run continuously for another 6 hrs and then close. The actual temp. is higher than the setting one which is to prevent from being too cool to your sleep. 2.In HEAT mode One hour after sleeping operation start, the temp. decreases 2 C lower than the setting one. After another hour decreases by 2 C more. The temperature will automatically rise by 1 C after an other 3 hrs operation ,and then automatically close after 3 hrs continuous operation.The actual temperature is lower than the setting one which is to prevent from being too hot to your sleep. 3.In AUTO mode. The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode. SLEEP RUN BEGINS SLEEP RUN STOPS about 6 hrs increase 1 C 1 hrs increase 1 C SETTING T SHUT DOWN In COOL,DRY mode SETTING T SHUT DOWN 1 hrs decrease 2 C 1 hrs decrease 2 C about 6 hrs 3 hrs increase 1 C SLEEP RUN BEGINS SLEEP RUN STOPS In HEAT mode Note: In Auto mode, the air conditioner will perform relative Sleep operation according to working mode. After setting Sleep function, it is not permitted to adjust clock. The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop. Set Sleep function after setting ìTimer Offî function, the air conditioner will perform Sleep function. After setting Sleep function, the Timer function cannot be set. Set Sleep function after setting ìTimer Onî function, the Sleep function can only be set in the set time of Timer On. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

11
Guide to Operation
Sleep Function
Use of SLEEP function
Before using this function, you should calibrate the clock first,
otherwise, the SLEEP function will be out of order.
Before going to bed, you can press the SLEEP button, the air
conditioner will operate in comfort sleep mode to make you
have a sound sleep.
After unit start,first set running mode and then press SLEEP button
once.Mark the air conditioner have the previous-set sleep time(first
power-on or after carrying out sleep function is 1h),the sleep symbol
will appear. Press time button
/
, you can choose the time in 1~8
hours.Each time the button is pressed the time increases/decreases
1 hour and ì xh î appears in the humidity setting part ,ì OFF î appears
in ì TIMER OFF î display part.
Press Sleep button again to cancel
Sleep function
and the sleep symbol disappears.
1.In COOL, DRY mode
One hour after sleeping operation start, the temp.
is 1 C higher than the setting one. After another
hour the temp. rises 1 C and then run continuously
for another 6 hrs and then close. The actual temp.
is higher than the setting one which is to prevent
from being too cool to your sleep.
2.In HEAT mode
One hour after sleeping operation start, the temp.
decreases 2 C lower than the setting one. After
another hour decreases by 2 C more. The temper-
ature will automatically rise by 1 C after an other
3 hrs operation ,and then automatically close after
3 hrs continuous operation.The actual temperature
is lower than the setting one which is to prevent
from being too hot to your sleep.
SLEEP RUN BEGINS
SLEEP RUN STOPS
SETTING T
SHUT DOWN
about 6 hrs
1 hrs
In COOL,DRY mode
increase 1 C
increase 1 C
SLEEP RUN BEGINS
SLEEP RUN STOPS
SETTING T
SHUT DOWN
1 hrs
1 hrs
3 hrs
about 6 hrs
increase 1 C
decrease 2 C
decrease 2 C
In HEAT mode
Note:
Operation Mode
3.In AUTO mode.
The air conditioner will run in corresponding sleep
operation according to the automatically selected
operation mode.
In Auto mode, the air conditioner will perform relative Sleep operation according to working mode.
After setting Sleep function, it is not permitted to adjust clock.
The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop.
Set Sleep function after setting ìTimer Offî function, the air conditioner will perform Sleep function.
After setting Sleep function, the Timer function cannot be set.
Set Sleep function after setting ìTimer Onî function, the Sleep function can only be set in the set time of
Timer On.
MODE
FAN
SWING
TEMP
CLOCK
SET
TIMER
SLEEP
RESET
FILTER RESET
ON/OFF
AM
SET
AM
OFF