Haier HBU-14HC03 User Manual - Page 31
Piping Connection
View all Haier HBU-14HC03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Installation Procedures Piping Connection Flare connection Indoor Unit Gas pipe 3-way valve Outdoor unit Liquid pipe (1) Dimension of connecting pipe 2-way valve Flare connection Gas pipe Liquid pipe 15.88mm 6.35mm Fit the nut on and fasten 90 + 0.5 (2) The maximum length and drop height of connecting pipe The maximum length is 10m The maximum drop height is 5m. To ensure the efficiency ,Pipes shall be as short as possible. Cautions for piping connection Spanner Do not twist or deform the connecting pipe. Do not mix dusts. The bending radius shall be as large as possible. Both gas pipe and liquid pipe shall be heat insulation. No leakage in the flare. Spanner Joint Nut (3) Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and tighten the nut, as shown in the figure. Pay attention to not mix foreign matters such as sands in. Diameter of Pipe Liquid Pipe 6.35mm Gas Pipe 15.88mm Tighten Torque 18 N. m 60N. m If not aligned ,tighten the nut by force will damage the nut that result in gas leakage 29