Installation of Outdoor Unit
View all Haier HBU-14HC03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Installation Procedures Installation of Outdoor Unit Selection of installation place Place strong enough to support unit weight, and will not cause vibration and noise. Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently ventilated. Place where is less affected by rain or direct sunlight and sea breeze. Place with enough space for smooth air flow. The unit cannot be installed on an unspecified metal frame (e.g. theft guard net). It shall be not less than 2.5m high from the ground if the outdoor unit is installed close to a street. Easy for maintenance. Fixing the unit Fix outdoor unit bracket to the wall using anchor bolt (M10). Fasten the outdoor unit onto the installation bracket with bolt (M10) and nut ,and keep it horizontal. If installation on the wall or on top of a roof, bracket shoukd be fixed securely to resist earthquake or storms. Be sure to use rubber pad during installation against unit vibration. Install the unit in such a way that the angle of inclination is lees than 3 degrees. 256 140 500 140 Installation dimension of outdoor unit (mm) 24