HP 1606 Fabric OS FCIP Administrators Guide v6.4.0 (53-1001766-01, November 20 - Page 79

Enabling persistently disabled ports, Before an FCIP tunnel can be used

Page 79 highlights

Enabling persistently disabled ports 3 IKE Policy 1 IPSec Policy 1 Pre-Shared Key qbcdefghijklmnopqrstuvwxyz123456 After FCIP tunnels are created, the configuration is saved in a persistent database. At this point, all configured FCIP tunnels now appear in the fabric as VE_Ports. 3. Verify that the VE_Port or VEX_Port is online, use the switchShow command to view and verify that the FCIP tunnel is online. switch:admin06> portenable 8/18 switch:admin06> portenable 8/19 switch:admin06> switchshow switchName:switch switchType:42.2 switchState:Online switchMode:Native switchRole:Subordinate switchDomain:4 switchId:fffc04 switchWwn:10:00:00:60:69:80:0d:bc zoning:ON (LSAN001) switchBeacon:OFF blade3 Beacon: OFF blade4 Beacon: OFF blade8 Beacon: OFF FC Router:ON FC Router BB Fabric ID:1 Area Slot Port Media Speed State 32 3 0 id N4 Online F-Port 50:03:0d:30:0d:13:00:09 33 3 1 id N4 Online F-Port 50:03:0d:30:0d:13:00:11 34 3 2 id N4 Online F-Port 50:03:0d:30:0d:13:00:13 35 3 3 id N4 Online F-Port 50:03:0d:30:0d:13:00:15 36 3 4 id N2 Online F-Port 21:00:00:e0:8b:08:bd:20 210 8 18 -- -- Online VE-Port 50:00:51:e3:51:55:3f:1e "fcr_xd_3_16" (downstream) 211 8 19 -- -- Online VE-Port 50:00:51:e3:70:42:5f:76 "fcr_xd_5_17" (downstream) 223 8 31 -- -- Offline 8 ge0 id 1G Online 8 ge1 id 1G Online Enabling persistently disabled ports Before an FCIP tunnel can be used, the associated ports must be persistently enabled. NOTE VEX_Port Users: If the fabric is already connected, you must leave the ge0 and ge1 ports disabled until after you have configured the VEX_Port; this will prevent unintentional merging of the two fabrics. Fabric OS FCIP Administrator's Guide 65 53-1001766-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Fabric OS FCIP Administrator’s Guide
65
53-1001766-01
Enabling persistently disabled ports
3
IKE Policy 1
IPSec Policy 1
Pre-Shared Key qbcdefghijklmnopqrstuvwxyz123456
After FCIP tunnels are created, the configuration is saved in a persistent database. At this
point, all configured FCIP tunnels now appear in the fabric as VE_Ports.
3.
Verify that the VE_Port or VEX_Port is online, use the
switchShow
command to view and verify
that the FCIP tunnel is online.
switch:admin06> portenable 8/18
switch:admin06> portenable 8/19
switch:admin06> switchshow
switchName:switch
switchType:42.2
switchState:Online
switchMode:Native
switchRole:Subordinate
switchDomain:4
switchId:fffc04
switchWwn:10:00:00:60:69:80:0d:bc
zoning:ON (LSAN001)
switchBeacon:OFF
blade3 Beacon:
OFF
blade4 Beacon:
OFF
blade8 Beacon:
OFF
FC Router:ON
FC Router BB Fabric ID:1
Area Slot Port Media Speed State
=====================================
32
3
0
id
N4
Online
F-Port
50:03:0d:30:0d:13:00:09
33
3
1
id
N4
Online
F-Port
50:03:0d:30:0d:13:00:11
34
3
2
id
N4
Online
F-Port
50:03:0d:30:0d:13:00:13
35
3
3
id
N4
Online
F-Port
50:03:0d:30:0d:13:00:15
36
3
4
id
N2
Online
F-Port
21:00:00:e0:8b:08:bd:20
<output truncated>
210
8
18 --
--
Online
VE-Port
50:00:51:e3:51:55:3f:1e
"fcr_xd_3_16" (downstream)
211
8
19 --
--
Online
VE-Port
50:00:51:e3:70:42:5f:76
"fcr_xd_5_17" (downstream)
<output truncated>
223
8
31
--
--
Offline
8
ge0
id
1G
Online
8
ge1
id
1G
Online
Enabling persistently disabled ports
Before an FCIP tunnel can be used, the associated ports must be persistently enabled.
NOTE
VEX_Port Users:
If the fabric is already connected, you must leave the ge0 and ge1 ports disabled
until
after you have configured the VEX_Port;
this will prevent unintentional merging of the two
fabrics.