HP 1606 Fabric OS FCIP Administrators Guide v6.4.0 (53-1001766-01, November 20 - Page 96
Displaying FCIP tunnel information (7800 switch and FX8-24 blade), output using the -c option.
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
4 Portshow command usage 23 0 ge0 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 1 ge1 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 2 ge5 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 3 ge4 Disable ----s 0s 0.00 0.00 0 200/1000 0 Flags: tunnel: c=compression f=fastwrite t=Tapepipelining F=FICON T=TPerf circuit: s=sack Displaying FCIP tunnel information (7800 switch and FX8-24 blade) The following example shows general tunnel information for a 7800 switch. switch:admin> portshow fciptunnel 16 portshow fciptunnel 16 Tunnel ID: 16 Tunnel Description: Admin Status: Enabled Oper Status: Up Compression: On (Moderate) Fastwrite: Off Tape Acceleration: Off TPerf Option: Off IPSec: Disabled Remote WWN: Not Configured Local WWN: 10:00:00:05:1e:55:59:e9 Peer WWN: 10:00:00:05:1e:55:68:05 Circuit Count: 4 Flags: 0x00000000 FICON: Off Displaying an FCIP tunnel with FCIP circuit information (7800 switch and FX8-24 blade) The following example adds circuit information to the fciptunnel output using the -c option. switch:admin> portshow fciptunnel 17 -c Tunnel ID: 17 Tunnel Description: Admin Status: Enabled Oper Status: Up Compression: On (Moderate) Fastwrite: Off Tape Acceleration: Off TPerf Option: Off IPSec: Disabled Remote WWN: Not Configured Local WWN: 10:00:00:05:1e:55:59:e9 Peer WWN: 10:00:00:05:1e:55:68:05 Circuit Count: 4 Flags: 0x00000000 FICON: Off Circuit ID: 16.0 Circuit Num: 0 Admin Status: Enabled 82 Fabric OS FCIP Administrator's Guide 53-1001766-01