Displaying FCIP tunnel information (7800 switch and FX8-24 blade), output using the -c option.

Page 96 highlights

4 Portshow command usage 23 0 ge0 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 1 ge1 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 2 ge5 Disable ----s 0s 0.00 0.00 0 200/1000 0 23 3 ge4 Disable ----s 0s 0.00 0.00 0 200/1000 0 Flags: tunnel: c=compression f=fastwrite t=Tapepipelining F=FICON T=TPerf circuit: s=sack Displaying FCIP tunnel information (7800 switch and FX8-24 blade) The following example shows general tunnel information for a 7800 switch. switch:admin> portshow fciptunnel 16 portshow fciptunnel 16 Tunnel ID: 16 Tunnel Description: Admin Status: Enabled Oper Status: Up Compression: On (Moderate) Fastwrite: Off Tape Acceleration: Off TPerf Option: Off IPSec: Disabled Remote WWN: Not Configured Local WWN: 10:00:00:05:1e:55:59:e9 Peer WWN: 10:00:00:05:1e:55:68:05 Circuit Count: 4 Flags: 0x00000000 FICON: Off Displaying an FCIP tunnel with FCIP circuit information (7800 switch and FX8-24 blade) The following example adds circuit information to the fciptunnel output using the -c option. switch:admin> portshow fciptunnel 17 -c Tunnel ID: 17 Tunnel Description: Admin Status: Enabled Oper Status: Up Compression: On (Moderate) Fastwrite: Off Tape Acceleration: Off TPerf Option: Off IPSec: Disabled Remote WWN: Not Configured Local WWN: 10:00:00:05:1e:55:59:e9 Peer WWN: 10:00:00:05:1e:55:68:05 Circuit Count: 4 Flags: 0x00000000 FICON: Off Circuit ID: 16.0 Circuit Num: 0 Admin Status: Enabled 82 Fabric OS FCIP Administrator's Guide 53-1001766-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

82
Fabric OS FCIP Administrator’s Guide
53-1001766-01
Portshow command usage
4
23
0 ge0
Disable ----s
0s
0.00
0.00
0
200/1000
0
23
1 ge1
Disable ----s
0s
0.00
0.00
0
200/1000
0
23
2 ge5
Disable ----s
0s
0.00
0.00
0
200/1000
0
23
3 ge4
Disable ----s
0s
0.00
0.00
0
200/1000
0
-------------------------------------------------------------------------------
Flags: tunnel: c=compression f=fastwrite t=Tapepipelining F=FICON T=TPerf
circuit: s=sack
Displaying FCIP tunnel information (7800 switch and FX8-24 blade)
The following example shows general tunnel information for a 7800 switch.
switch:admin> portshow fciptunnel 16
portshow fciptunnel 16
-------------------------------------------
Tunnel ID: 16
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
Displaying an FCIP tunnel with FCIP circuit information (7800 switch
and FX8-24 blade)
The following example adds circuit information to the
fciptunnel
output using the -c option.
switch:admin> portshow fciptunnel 17 -c
-------------------------------------------
Tunnel ID: 17
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
-------------------------------------------
Circuit ID: 16.0
Circuit Num: 0
Admin Status: Enabled