HP 3PAR StoreServ 7200 2-node HP 3PAR StoreServ 7000 Storage Service Guide (QR
HP 3PAR StoreServ 7200 2-node Manual
View all HP 3PAR StoreServ 7200 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 3PAR StoreServ 7200 2-node manual content summary:
- HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 1
HP 3PAR StoreServ 7000 Storage Service Guide Abstract This guide provides information about maintenance and upgrading HP 3PAR StoreServ 7000 Storage system hardware components for authorized technicians. HP Part Number: QR482-96503 Published: September 2013 Edition: 1 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 3
FC) Adapter LEDs 33 Converged Network Adapter (CNA) LEDs 34 Node FC and CNA Port Numbering 34 SAS Port LEDs...35 Interconnect Port LEDs...36 Verifying Service Processor LEDs 36 3 Support and Other Resources 39 Contacting HP...39 HP 3PAR documentation...39 Typographic conventions...42 Contents 3 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 4
Node 44 Connecting the Laptop to the HP 3PAR Service Processor 44 Serial Cable Connections...44 Maintenance PC Connector Pin-outs 44 Service Processor Connector Pin-outs 45 Manually Initializing the Storage System Software 45 Manually Setting up the Storage System 45 Installing HP 3PAR - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 5
the HP 3PAR StoreServ 7000 Storage systems. CAUTION: Before servicing any component in the storage system, Guided Maintenance or the SPMAINT (Service Processor Maintenance) in the Command Line Interface (CLI), where you perform various administrative and diagnostic tasks to support both the storage - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 6
available for self repair. For assistance, contact an HP-authorized service provider to replace the part. These parts include the drive and node enclosures, the I/O modules, PCMs, and internal components of the controller node in the HP 3PAR StoreServ 7000 systems. Types of CSR components include - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 7
Figure 2 Product label with HP Spare part number Swappable Components Colored touch points on a storage system component (such as a lever or until the replacement can be made. Drives must be replaced within 10 minutes, nodes 30 minutes and all other parts within 6 minutes. • Before replacing a hot - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 8
see Figure 3 (page 8)). Figure 3 Verify Drive Failure Alert 2. At the HP Storage Systems Guided Troubleshooting web site, follow the link for your product. 3. At the bottom of the HP 3PAR product page, click the link for HP 3PAR Alert Messages. 4. At the bottom of the Alert Messages page, choose the - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 9
This can seriously impact host access to data. 3. Turn off power to the node PCMs. 4. Turn off power to the drive enclosure PCMs. 5. Turn off all Pivot Brackets To access the vertically mounted power distribution units (PDU) or servicing area, the PDUs can be lowered out of the rack. 1. Remove the - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 10
on the node enclosure PCMs. 10. Verify the status of the LEDs, see "Understanding LED Indicator Status" (page 26). Repairing a Disk Drive Use the following instructions for replacing failed disk drives or solid-state drives (SSD). WARNING! If the StoreServ is enabled with HP 3PAR Data Encryption - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 11
service life of an HP 3PAR StoreServ under the great majority of configurations, IO patterns, and workloads. HP 3PAR StoreServ tracks HP support contracts. Identifying a Disk Drive 1. Under the Systems tree in the left panel of HP 3PAR Management Console, select the storage system to be serviced - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 12
Failed drive (see Figure 8 (page 12)). Figure 8 Cage Link for Failed Drive 3. Select the Locate icon in the top toolbar of the Management Console. 12 Servicing the Storage System - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 13
Figure 9 Tool Bar Locate Icon 4. In the Locate Cage dialog box, enter an appropriate time to allow service personnel to view the LED status of the Drive Enclosure (Cage). See Figure 10 (page 13). NOTE: If necessary, use the Stop Locate icon to - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 14
Figure 11 7200 and 7400 Two Node System (HP M6710 Drive Enclosure) Removing a 3.5 inch Disk To remove a 3.5 inch disk drive: 1. Pinch the latch in the handle reinstall a new disk drive, see "Installing a Disk Drive" (page 15). Figure 12 Removing a 3.5 inch disk drive 14 Servicing the Storage System - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 15
based on drive type, speed, and capacity. For more information, see Guidelines for Installing Disk Drives in Disk Enclosures in the HP 3PAR StoreServ 7000 Storage Installation Guide firmly until it clicks. Figure 13 7200 and 7400 Two Node System (HP M6710 Drive Enclosure) Installing a 3.5 inch disk - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 16
resort. NOTE: Until data has been restored, the original disk drive will display as Failed and the replacement disk drive will display as Degraded. 16 Servicing the Storage System - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 17
take several hours. When the process is complete, the failed drive is dismissed and dropped from the display. Disk Drive Numbering Figure 15 7200 and 7400 2-Node - displayed as DCN1 in software output Figure 16 7400 4 Controller Node Displayed as DCN1 in Software Output Repairing a Disk Drive 17 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 18
replaced, and the location of the failed node, if replacement is required. CAUTION: Customers should replace a controller node only on StoreServ 7200 Storage; other internal components should be serviced by ASPs. NOTE: Do not order a replacement node until the ASP has verified the failure, including - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 19
align the riser card with the slot on the node. Snap the PCIe adapter assembly into the node. 4. Replace the node cover: a. While aligning the node rod with the cutout in the front, and the guide pins with the cutouts in the side, lower the node cover into place. b. Tighten the two thumbscrews to - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 20
that the node has joined the cluster. 9. Follow the return instructions provided with the new component. NOTE: If a PCIe adapter is installed in the failed node, leave it installed. Do not remove and return it in the packaging for the replacement PCIe adapter. 20 Servicing the Storage System - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 21
HBA/CNA and there are two to six SFPs per node. Before you begin, use either SPMAINT or the HP 3PAR Management Console to identify the failed SFP. SFP Identification 1. Under the Systems tree in the left panel, select the storage system to be serviced. 2. On the Summary tab, click the Port link to - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 22
Type as Host. To perform maintenance using CLI, access SPMAINT: 1. In the 3PAR Service Processor Menu, select option 7 Interactive CLI for an InServ. 2. Issue the loss_sync - 2C27D75301F6 iscsi iSCSI - - - 0:2:2 target loss_sync - 2C27D75301F2 iscsi iSCSI 22 Servicing the Storage System - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 23
to verify which SFP requires replacement: cli%showport -sfp N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM 0:1:1 OK HP-F 8.5 No No No Yes 0:1:2 OK HP-F 8.5 No No No Yes 0:2:1 OK AVAGO 10.3 No No Yes Yes 0:2:2 OK AVAGO 10.3 No No Yes Yes 1:1:1 OK - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 24
No Yes 1:2:1 OK HP-F 8.5 No No Yes Yes 1:2:2 OK HP-F 8.5 No No Yes Yes 1:2:3 OK HP-F 8.5 No No Yes Yes 1:2:4 OK HP-F 8.5 No No Yes Yes Open the HP 3PAR Management Console 1. Under the Systems tree in the left panel, select the storage system to be serviced to connect. 2. On - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 25
SFP. See "Replacing an SFP" (page 25). 6. In the HP 3PAR Management Console, verify that the SFP is successfully replaced. The replaced the cable. 4. Place the failed SFP into the packaging for return to HP. 5. Reconnect the cable to the SFP module and verify that the link status LED is solid green - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 26
2 Understanding LED Indicator Status Storage system components have LEDs to indicate status of the hardware and whether it is functioning properly. These indicators help diagnose basic hardware problems. You can quickly identify hardware problems by examining the LEDs on all components using the - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 27
for failed disk drives do not blink. The I/O module Fault LEDs at the rear of the enclosure also blink. Normal operation Activity Storage System Component LEDs The storage system includes the following components in the enclosure at the rear of the system. Power Cooling Module LEDs The PCM has four - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 28
Figure 26 PCM LEDs The following table describes the LED states. Table 3 PCM LED Descriptions Icon LED Appearance On AC input fail Amber Flashing Indicates No AC power or PCM fault Firmware download PCM OK Green On Flashing AC present and PCM On / OK Standby mode Fan Fail Amber On - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 29
PCM OK Green On Flashing AC Present and PCM On / OK Standby mode Fan Fail Amber On Flashing PCM fail or PCM fault Firmware download Storage System Component LEDs 29 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 30
Table 4 Drive PCM LED Descriptions (continued) Icon LED Appearance On DC Output Fail Amber Flashing Indicates No AC power or fault or out of tolerance Firmware download I/O Modules LEDs I/O modules are located on the back of the system. I/O modules have two mini-SAS universal ports, which - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 31
Port Activity; 4 LEDs for Data Ports 0 through 3 Appearance Green State On Off Flashing Controller Node and Internal Component LEDs Controller node LEDs are shown in the following table. Figure 31 Controller Node LEDs Meaning Ready, no activity Not ready or no power Activity NOTE: Issue the - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 32
Off Flashing 1 GbE Link 100 Mb Link No link established or 10 Mb Link No link activity No link established Link activity Node FC and CNA Port LEDs The controller node has two FC ports; each includes two LEDs. The arrow head-shaped LEDs point to the port they are associated with - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 33
(dead device) or power is not applied Not connected Connected at 4GB/s Connected at 4GB/s Normal/Connected - link up Link down or not connected Controller Node and Internal Component LEDs 33 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 34
CNA LEDs Upper Link Lower ACT (Activity) Green Green Off Link down On Link up Off No activity On Activity Node FC and CNA Port Numbering Port position is displayed as Node:Slot:Port (N:S:P) in the Management Console. Figure 36 FC Ports Table 11 FC Ports Port FC-1 FC-2 Figure 37 FC - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 35
12 FC Adapter Ports Port 1 2 3 4 Figure 38 CNA Ports Slot:Port 2:1 2:2 2:3 2:4 Table 13 CNA Ports Port 1 2 Slot:Port 2:1 2:2 SAS Port LEDs The controller node has two SAS ports and each includes four LEDs, numbered 0-3: Figure 39 SAS port LEDs Controller Node and Internal Component LEDs 35 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 36
Ports LEDs Figure 41 7400 Interconnect Ports LEDs Table 15 Interconnect port LEDs 7200 7400 A 7200 does not node in wrong slot 3. Serial number mismatch between controller nodes Status Green On Off Link established Link not yet established Verifying Service Processor LEDs The HP 3PAR - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 37
system health is normal System health is degraded System health is critical System power is off Linked to network Network activity No network link Verifying Service Processor LEDs 37 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 38
Table 17 Rear panel LEDs Item LED 1 NIC link 2 NIC status 3 UID LED/button 4 Power supply Appearance Green Off Green or Flashing Green Off Blue Flashing Blue Off Green Off Description Link No link Activity No activity Active System is being managed remotely Deactivated Normal Off = one or more of - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 39
or Service Agreement ID (if applicable) • Product serial numbers • Error messages • Operating system type and revision level • Detailed questions Specify the type of support you are requesting: HP 3PAR storage system HP 3PAR StoreServ 7200, 7400, and 7450 Storage systems HP 3PAR StoreServ 10000 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 40
detailed alert information HP 3PAR F-Class, T-Class, and StoreServ 10000 Storage Troubleshooting Guide Installing, configuring, and maintaining the HP 3PAR Policy HP 3PAR Policy Server Installation and Setup Guide Server HP 3PAR Policy Server Administration Guide 40 Support and Other Resources - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 41
3PAR StoreServ 7000 Storage Service Guide HP 3PAR StoreServ 7450 Storage Service Guide Troubleshooting 7200, 7400, and 7450 storage systems HP 3PAR StoreServ 7000 Storage Troubleshooting Guide HP 3PAR StoreServ 7450 Storage Troubleshooting Guide Maintaining the Service Processor HP 3PAR Service - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 42
followed as directed in order to achieve a functional and supported implementation based on testing at HP. HP 3PAR branding information • The server previously referred to as the "InServ" is now referred to as the "HP 3PAR StoreServ Storage system." • The operating system previously referred to as - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 43
4 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ([email protected]). Include the document title and part number, version number, or the URL when - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 44
or SPOCC to perform maintenance procedures. For more information on servicing the storage system, see the HP 3PAR StoreServ 7000 Storage Service Guide. Connecting the Laptop to the Controller Node Connect the RJ45 cable to the controller node MFG ports (known as the public interface) to the laptop - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 45
Laptop to the SP" in the HP 3PAR StoreServ 7000 Storage Installation Guide. Manually Setting up the Storage System The Out-of-the-Box (OOTB) script guides you through setting up and configuring the storage system software: 1. Connect the PC to the controller node 0 through a serial cable and log in - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 46
is in a proper manual startup state to proceed. Cluster has the following nodes: Node 0: Node 1: ... Is this nodes in the system, then type c and press Enter. If the system is not ready for the system setup script, an error message appears. After following any instructions and correcting any problems - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 47
quit ==> c 9. Verify the number of drives in the storage system. Type c and press Enter to continue. 10. HP recommends that at least four physical disks worth of chunklets be designated as spares to support , but is not recommended as spares must be manually added when new disks are added. Enter "Ma - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 48
setup, contact your local service provider for technical support to obtain the proper license HP 3PAR OS Files After completing the Service Processor Setup wizard process, HP 3PAR OS files must first be installed onto the SP in order to communicate and add a storage system. NOTE: If the StoreServ - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 49
is complete. 1.1 Display SP Version SP Software Version SP-4.1.0.GA-97 SP Base Image Version: Red Hat Enterprise Linux Server release 6.1 (Santiago) SP Version data. Press to continue Continue to "Adding a Storage System to the Service Processor" (page 50). Installing HP 3PAR OS Files 49 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 50
service, and monitor the health of the system. NOTE: Beginning with HP 3PAR SP OS 4.1.0 MU2, only the StoreServ with a serial number associated with the SP ID can be attached to the SP. For assistance with adding the StoreServ to SP, contact HP Support. To add the storage Storage Software Manually - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 51
3PAR system name found for SYSID found for serial number found for Writing configuration file for ... verifying / adding cli service storage system HP 3PAR Implementation Guides - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 52
node, PCI slot, and PCI adapter port to be controlled. 5. When finished setting each connected target port, verify that all ports are set correctly. 192.168.46.249 cli% showport -par Creating and Exporting Test Volumes For more information about the commands used in this section, see the HP 3PAR - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 53
5. Repeat steps 1 through 4 for each host. 6. From the SP, type exit to stop the CLI session, then type x and press Enter to return to the SP main menu. Type x and press Enter again to exit. Type exit and press Enter to log off the SP. Disconnect the cables between the SP and the maintenance PC. - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 54
B Node Rescue Service Processor (Physical) Node Rescue The SP node rescue should be used only in cases when the storage system includes a physical SP and no nodes remain in the cluster or when all nodes are down. NOTE: For SP node rescue, you can specify whether to use the public Ethernet port (MGMT - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 55
system 7. Issue the following commands: • shownode to verify that all nodes have joined the cluster. cli% shownode Control Data Cache Node Name -State- Master InCluster --LED-- Mem(MB) Mem(MB) . 8. Click the SPMAINT menu button, then click Sign Out. Service Processor (Physical) Node Rescue 55 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 56
Catalog The following shows each component of the storage system for all replaceable hardware parts including the part number, full description, quantity, and CSR type. Drive Enclosure Components Figure 46 HP M6710 Drive Enclosure (2U24) Figure 47 HP M6720 Drive Enclosure (4U24) 56 Illustrated Parts - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 57
Figure 48 2.5-inch SFF disk drive Figure 49 3.5-inch LFF disk drive Table 19 Drive Chassis FRUs Material Number Description 683232-001 SPS-Enclosure Midplane 2U24 Assy 683233-001 SPS-Enclosure Midplane 4U24 Assy 683234-001 SPS-Drive Carrier SFF SSD Assy 683235-001 SPS-Drive Carrier LFF - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 58
2TB 7.2K LFF SAS 743181-001 SPS-HDD SS7000 3TB 7.2K LFF SAS 743183-001 SPS-HDD SS7000 4TB 7.2K LFF SAS Storage System Components Figure 50 764 W Power Cooling Module without Battery CSR Type Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 59
Figure 51 764 W Power Cooling Module Battery Figure 52 580 W Power Cooling Module Figure 53 I/O Module Storage System Components 59 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 60
Table 20 Storage System Components Part Number 683239-001 727386-001 683240-001 683241-001 683251-001 Description SPS-PCM 764W Assy SPS-PCM 764W Assy, Gold SPS-Battery PCM 764W Assy SPS-PCM 580W Assy SPS-Module I/O SASquatch Controller Node and Internal Components Figure 54 Controller Node Qty. - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 61
Figure 56 4-port Fibre Channel Adapter Figure 57 2-port CNA Adapter Figure 58 FC SFP Adapter Controller Node and Internal Components 61 - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 62
-001 683237-001 468508-002 Description SPS-Node Module 7200 NO HBA SPS-Node Module 7400 NO HBA SPS-Node Boot Drive (Node drive) SPS-Adapter FC 4port SPS-Adapter CNA 2port SPS-Module FC SFP Figure 59 Internal Node Components Qty. 2 4 1 per node 1 1 Up to 4 per node CSR Type Optional Not Not Not - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 63
Number 725287-001 Description Qty HP 3PAR Service Processor DL320e 1 Miscellaneous Cables and Parts Table 24 Storage System Cables Part Number 683808-001 683809-001 683810-001 683252-001 Description Qty. SPS-Cable Node Link PCIe 7400 SPS-Cable Console Node SPS-Cable Console Drive Chassis - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 64
Table 24 Storage System Cables (continued) Part Number 656427-001 656428-001 656429-001 656430- SPS-Bezel M6720 drive shelf, left 683257-001 SPS-Bezel 7200, right 683258-001 SPS-Bezel 7400, left 690777-001 SPS-Bezel M6720 drive shelf, right 64 Illustrated Parts Catalog CSR Type Mandatory - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 65
5183-5691 C7542A Description Qty. SPS-Processor 1U Mounting Kit SPS-Service Processor 1U Mounting Kit SPS-CABLE ADAPTER SERVICE PROCESSOR SPS-Service Processor DL360e Ethernet Cable 25 ft CAT5 M/M Ethernet Cable 50 ft. CAT5 RJ45 M/M HP Ethernet 15.2m (50 ft) CAT5e RJ45 M/M Cable CSR Type - HP 3PAR StoreServ 7200 2-node | HP 3PAR StoreServ 7000 Storage Service Guide (QR - Page 66
of drives in disk drives - showpd • Storage system hardware configuration • Number of enclosures and nodes • Physical condition of system hardware and cabinet Storage System Components from an Existing or Third Party Rack See the appropriate component removal procedures in "Servicing the Storage
HP 3PAR StoreServ 7000 Storage Service
Guide
Abstract
This guide provides information about maintenance and upgrading HP 3PAR StoreServ 7000 Storage system hardware
components for authorized technicians.
HP Part Number: QR482-96503
Published: September 2013
Edition: 1