Changing the CCA Setting, Using the File Transfer Monitor

Page 22 highlights

Changing the CCA Setting NOTE: If the SP is running in Secure Network Mode (including A-class users), you will not be able to change the CCA setting. To change the Customer Controlled Access setting by using SPOCC: 1. On the SPOCC home page, click the SPmaint tab. 2. Click Network Configuration. 3. Click Customer Controlled Access. To change the CCA setting by using SPMAINT: 1. Log in to the SPMAINT utility. 2. From the SP Main menu, select option 2 for Network Configuration. 3. Select option 1 for Customer Controlled Access. 4. Select option 1 (Turn off HQ communications), 2 (Set outbound only HQ communications), or 3 (Set Bi-directional HQ Communications) to change the HQ connectivity control setting (see for details). 5. Type s, and then press ENTER to save and apply the new setting. Using the File Transfer Monitor The HQ File Transfer Monitor feature displays information about the latest (or current) transfer and latest prior transfer from the Service Processor to the connection portal. This feature is interactive in nature, and after it is initiated, it must be stopped manually as described in this section. To start the File Transfer Monitor by using SPOCC: 1. On the SPOCC home page, click the SPmaint tab. 2. Click SP Control/Status. 3. Click File Transfer Monitor. The monitor opens in a new window. To start the File Transfer Monitor by using SPMAINT: 1. Log in to the SPMAINT utility. 2. From the SP Main menu, select option 1 for SP Control/Status, and then press ENTER. 3. Select option 6, File Transfer Monitor, and then press ENTER To stop the File Transfer Monitor, on the transfer monitor menu, type q. 22 HP 3PAR Communication Settings

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

Changing the CCA Setting
NOTE:
If the SP is running in Secure Network Mode (including A-class users), you will not be
able to change the CCA setting.
To change the Customer Controlled Access setting by using SPOCC:
1.
On the SPOCC home page, click the
SPmaint
tab.
2.
Click
Network Configuration
.
3.
Click
Customer Controlled Access
.
To change the CCA setting by using SPMAINT:
1.
Log in to the SPMAINT utility.
2.
From the SP Main menu, select option
2
for
Network Configuration
.
3.
Select option
1
for
Customer Controlled Access
.
4.
Select option
1 (Turn off HQ communications)
,
2 (Set outbound only HQ communications)
, or
3 (Set Bi-directional HQ Communications)
to change the HQ connectivity control setting (see
for details).
5.
Type
s
, and then press
ENTER
to save and apply the new setting.
Using the File Transfer Monitor
The HQ File Transfer Monitor feature displays information about the latest (or current) transfer and
latest prior transfer from the Service Processor to the connection portal. This feature is interactive
in nature, and after it is initiated, it must be stopped manually as described in this section.
To start the File Transfer Monitor by using SPOCC:
1.
On the SPOCC home page, click the
SPmaint
tab.
2.
Click
SP Control/Status
.
3.
Click
File Transfer Monitor
. The monitor opens in a new window.
To start the File Transfer Monitor by using SPMAINT:
1.
Log in to the SPMAINT utility.
2.
From the SP Main menu, select option
1
for
SP Control/Status
, and then press
ENTER
.
3.
Select option
6
,
File Transfer Monitor
, and then press
ENTER
To stop the File Transfer Monitor, on the transfer monitor menu, type
q
.
22