HP 3PAR StoreServ 7450 4-node HP 3PAR StoreServ 7450 Storage Troubleshooting G - Page 19

Ethernet LEDs, FC Port LEDs, Table 8 Controller Node LEDs, Ethernet LEDs

Page 19 highlights

Table 8 Controller Node LEDs Callout 1 LED Status Appearance Green 2 Hotplug Blue 3 Fault Amber Indicates Node status Good • On - No cluster • Quick Flashing - Boot • Slow Flashing - Cluster Node FRU Indicator • On - OK to remove • Off - Not OK to remove • Flashing - locatenode command has been issued Node status Fault • On - Fault • Off - No fault • Flashing - Node in cluster and there is a fault Ethernet LEDs The controller node has two built-in Ethernet ports and each includes two LEDs: Figure 20 Ethernet LEDs Table 9 Ethernet LEDs Callout 1 LED Link Up Speed Appearance Green Amber 2 Activity Green Indicates On - 1 Gbe Link On - 100 Mbit Link Off - No link established or 10 Mbit Link On - No Link activity Off - No link established Flashing - Link activity FC Port LEDs The controller node has two FC ports and each includes two LEDs. The arrow heads shaped LEDs point to the port they are associated with. The following illustration shows the LEDs associated with the FC-1 port. Controller Node and Internal Component LEDs 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Table 8 Controller Node LEDs
Indicates
Appearance
LED
Callout
Node status Good
Green
Status
1
On – No cluster
Quick Flashing – Boot
Slow Flashing – Cluster
Node FRU Indicator
Blue
Hotplug
2
On – OK to remove
Off – Not OK to remove
Flashing –
locatenode
command has been
issued
Node status Fault
Amber
Fault
3
On – Fault
Off – No fault
Flashing – Node in cluster and there is a fault
Ethernet LEDs
The controller node has two built-in Ethernet ports and each includes two LEDs:
Figure 20 Ethernet LEDs
Table 9 Ethernet LEDs
Indicates
Appearance
LED
Callout
On – 1 Gbe Link
Green
Link Up
Speed
1
On – 100 Mbit Link
Amber
Off – No link established or 10 Mbit Link
On – No Link activity
Green
Activity
2
Off – No link established
Flashing – Link activity
FC Port LEDs
The controller node has two FC ports and each includes two LEDs. The arrow heads shaped LEDs
point to the port they are associated with. The following illustration shows the LEDs associated with
the FC-1 port.
Controller Node and Internal Component LEDs
19