HP 3PAR StoreServ 7450 4-node HP 3PAR StoreServ 7450 Storage Troubleshooting G - Page 33

Cage Example 2, Cage Suggested Action 2, A cage power supply or power supply fan is failed

Page 33 highlights

0:2 2000001862953303 Green 35 0xdc Loop fail 0xdc OK 0:3 2000001862953888 Green 31 0xda Loop fail 0xda OK cli% showcage -sfp cage4 Cage FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM 4 0 0 OK FINISAR CORP. 4.1 No No Yes Yes 4 1 1 OK FINISAR CORP. 4.1 No No No Yes cli% showcage -sfp -ddm cage4 ---------Cage 4 Fcal 0 SFP 0 DDM---------- -Warning- --Alarm-- --Type-- Units Reading Low High Low High Temp C 33 -20 90 -25 95 Voltage mV 3147 2900 3700 2700 3900 TX Bias mA 7 2 14 1 17 TX Power uW 394 79 631 67 631 RX Power uW 0 15 794 10* 1259 ---------Cage 4 Fcal 1 SFP 1 DDM---------- -Warning- --Alarm-- --Type-- Units Reading Low High Low High Temp C 31 -20 90 -25 95 Voltage mV 3140 2900 3700 2700 3900 TX Bias mA 8 2 14 1 17 TX Power uW 404 79 631 67 631 RX Power uW 402 15 794 10 1259 Cage Example 2 Component Description Qty Cage Degraded or failed cage power supplies 2 Cage Degraded or failed cage AC power 1 Component -Identifier Description------------ Cage cage:1 Power supply 0 is Failed Cage cage:1 Power supply 0's AC state is Failed Cage cage:1 Power supply 2 is Off Cage Suggested Action 2 A cage power supply or power supply fan is failed, is missing input AC power, or the switch is turned OFF. The showcage -d cageX and showalert commands provide more detail. cli% showcage -d cage1 Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side 1 cage1 0:0:2 0 1:0:2 0 24 27-39 2.37 2.37 DC2 n/a -----------Cage detail info for cage1 --------- Interface Board Info FCAL0 FCAL1 Link A RXLEDs Green Off Link A TXLEDs Green Off Link B RXLEDs Off Green Link B TXLEDs Off Green LED(Loop_Split) Off Off LEDS(system,hotplug) Amber,Off Amber,Off -----------Midplane Info----------- Firmware_status Current Product_Rev 2.37 State Normal Op Loop_Split 0 Troubleshooting Storage System Components 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

0:2 2000001862953303 Green
35 0xdc Loop fail 0xdc
OK
0:3 2000001862953888 Green
31 0xda Loop fail 0xda
OK
cli% showcage -sfp cage4
Cage FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
4
0
0 OK
FINISAR CORP.
4.1 No
No
Yes
Yes
4
1
1 OK
FINISAR CORP.
4.1 No
No
No
Yes
cli% showcage -sfp -ddm cage4
---------Cage 4 Fcal 0 SFP 0 DDM----------
-Warning- --Alarm--
--Type-- Units Reading Low
High Low
High
Temp
C
33
-20
90
-25
95
Voltage
mV
3147
2900 3700 2700 3900
TX Bias
mA
7
2
14
1
17
TX Power uW
394
79
631
67
631
RX Power uW
0
15
794
10*
1259
---------Cage 4 Fcal 1 SFP 1 DDM----------
-Warning- --Alarm--
--Type-- Units Reading Low
High Low
High
Temp
C
31
-20
90
-25
95
Voltage
mV
3140
2900 3700 2700 3900
TX Bias
mA
8
2
14
1
17
TX Power uW
404
79
631
67
631
RX Power uW
402
15
794
10
1259
Cage Example 2
Component -------------Description-------------- Qty
Cage
Degraded or failed cage power supplies
2
Cage
Degraded or failed cage AC power
1
Component -Identifier- ------------Description------------
Cage
cage:1
Power supply 0 is Failed
Cage
cage:1
Power supply 0's AC state is Failed
Cage
cage:1
Power supply 2 is Off
Cage Suggested Action 2
A cage power supply or power supply fan is failed, is missing input AC power, or the switch is
turned OFF. The
showcage -d cageX
and
showalert
commands provide more detail.
cli% showcage -d cage1
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
RevA RevB Model Side
1 cage1 0:0:2
0 1:0:2
0
24 27-39 2.37 2.37 DC2
n/a
-----------Cage detail info for cage1 ---------
Interface Board Info
FCAL0
FCAL1
Link A RXLEDs
Green
Off
Link A TXLEDs
Green
Off
Link B RXLEDs
Off
Green
Link B TXLEDs
Off
Green
LED(Loop_Split)
Off
Off
LEDS(system,hotplug) Amber,Off Amber,Off
-----------Midplane Info-----------
Firmware_status
Current
Product_Rev
2.37
State
Normal Op
Loop_Split
0
Troubleshooting Storage System Components
33