Not Supported: NS/Remote Ports Method applies to local ports, Use of Timeout Parameter Not Supported.

Page 25 highlights

Property contains the value 5=No Change. All port state changes are atomic; there is no pending requested state. (NS/Remote) Property contains the enumerated value 12=Not Applicable. EnableDefault (Local) Property contains the configured port state. • 02-Enabled: Port is enabled • 03-Disabled: Port is disabled (NS/Remote) • Property contains the enumerated value 5=Not Applicable. RequestStateChange (Local only) Method changes the configured port state to the RequestedState value. If the RequestedState parameter is 11-Reset, the port is reset, but the configured state does not change. Parameters: • RequestedState: [required] A port specific array of valid values may be found in the FCPortCapabilities.RequestedStatesSupported property. Parameter must be one of the following enumerated values. • 2-Enabled: Port is online. • 3-Disabled: Port is offline • 7-Test: Port is in diagnostics mode. • 11-Reset: Port is reset. • Job: Ignored, command is synchronous. • TimeoutPeriod: must be zero second interval, or NULL, command is synchronous. Method Returns: • 0-Success • 1-Not Supported: (NS/Remote Ports) Method applies to local ports only. • 6-In Use: Switch is being configured by another user. • 4097-Invalid State Transition: RequestedState parameter value is out of range. • 4098-Use of Timeout Parameter Not Supported. Request Status Codes: • CIM_ERR_ACCESS_DENIED: User does not have authorization for this command. • CIM_ERR_INVALID_PARAMETER: One or more required parameters are missing. • CIM_ERR_NOT_FOUND: The FCPort instance was not found. Extended properties and methods HealthState (Local Only) Property reports the diagnostic status of the port as a result of the switch POST. Supported values are: • 0-Unknown Port is not installed • 5-OK No errors • 25-Critical Failure Port failed POST IOStreamGuardState (Local Only) HP StorageWorks 8/20q and SN6000 Fibre Channel Switch CIM Agent Reference Guide 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

HP StorageWorks 8/20q and SN6000 Fibre Channel Switch CIM Agent Reference Guide
25
Property contains the value
5=No Change
. All port state changes are atomic; there is no pending
requested state.
(NS/Remote)
Property contains the enumerated value
12=Not Applicable
.
EnableDefault
(Local)
Property contains the configured port state.
02
Enabled
: Port is enabled
03
Disabled
: Port is disabled
(NS/Remote)
Property contains the enumerated value
5=Not Applicable
.
RequestStateChange
(Local only)
Method changes the configured port state to the
RequestedState
value. If the
RequestedState
parameter is
11-Reset
, the port is reset, but the configured state does not
change.
Parameters:
RequestedState
: [required] A port specific array of valid values may be found in the
FCPortCapabilities.RequestedStatesSupported
property. Parameter must be one of
the following enumerated values.
2
Enabled
: Port is online.
3
Disabled
: Port is offline
7
Test
: Port is in diagnostics mode.
11
Reset
: Port is reset.
Job
: Ignored, command is synchronous.
TimeoutPeriod:
must be zero second interval, or NULL, command is synchronous.
Method Returns:
0-Success
1-Not Supported: (NS/Remote Ports) Method applies to local ports
only.
6-In Use: Switch is being configured by another user.
4097-Invalid State Transition: RequestedState parameter value is out
of range.
4098-Use of Timeout Parameter Not Supported.
Request Status Codes:
CIM_ERR_ACCESS_DENIED
: User does not have authorization for this command.
CIM_ERR_INVALID_PARAMETER
: One or more required parameters are missing.
CIM_ERR_NOT_FOUND
: The FCPort instance was not found.
Extended properties and methods
HealthState
(Local Only)
Property reports the diagnostic status of the port as a result of the switch POST. Supported values
are:
0-Unknown Port is not installed
5-OK No errors
25-Critical Failure Port failed POST
IOStreamGuardState
(Local Only)