HP 8/20q HP StorageWorks 8/20q Fibre Channel Switch QuickTools Switch Manageme - Page 67

Table 12 SNMP Properties dialog box fields, Error, Warning, Notify, Info, Debug, and Mark

Page 67 highlights

Table 12 describes the SNMP Properties dialog box fields. Table 12 SNMP Properties dialog box fields Field Description SNMP Enabled Enables or disables SNMP communication with other switches in the fabric. The user cannot use an SNMP application at a workstation to talk to a switch that has this setting disabled. Contact Specifies the name (up to 64 characters) of the person who is to be contacted to respond to trap events. The default is . Read Community Read community password (up to 32 characters) that authorizes an SNMP agent to read information from the switch. This is a write-only field. The Read Community value on the switch and the SNMP management server must be the same. The default is public. SNMP Proxy Enables or disables the use of SNMP to monitor and configure switches in the fabric. Location Specifies the name (up to 64 characters) for the switch location. The default is . Authentication Trap Enables or disables the reporting of SNMP authentication failures. If enabled, a notification trap is sent when incorrect community string values are used. The default value is False. Write Community Write community password (up to 32 characters) that authorizes an SNMP client to write information to the switch. This is a write-only field. The value on the switch and the SNMP management server must be the same. The default value is private. Trap Version Specifies the SNMP version (1 or 2) with which to format traps. Trap 1 Enabled Enables or disables the trap. If disabled, traps are not sent to trap monitoring stations and the trap settings are not configurable. Trap Address Specifies the IP address to which SNMP traps are sent. A maximum of 5 trap addresses are supported. The default address for trap 1 is 10.0.0.254. The default address for traps 2-5 is 0.0.0.0. Trap Community Trap Severity Trap community password (up to 32 characters) that authorizes an SNMP agent to receive traps. This is a write-only field. The value on the switch and the SNMP management server must be the same. The default is public. Specifies a severity level to assign to the trap. Open the drop-down list and choose a level. The Trap 1 Enabled option on the SNMP Properties dialog box must be enabled to access this drop-down list. Trap severity levels include Unknown, Emergency, Alert, Critical, Error, Warning, Notify, Info, Debug, and Mark Trap Port Specifies the port number (between 1-65535) on which a trap is set. The default is 162. HP StorageWorks 8/20q Fibre Channel Switch QuickTools Switch Management User Guide 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

HP StorageWorks 8/20q Fibre Channel Switch QuickTools Switch Management User Guide
67
Table 12
describes the SNMP Properties dialog box fields.
Table 12
SNMP Properties dialog box fields
Field
Description
SNMP Enabled
Enables or disables SNMP communication with other switches in the
fabric. The user cannot use an SNMP application at a workstation to
talk to a switch that has this setting disabled.
Contact
Specifies the name (up to 64 characters) of the person who is to be
contacted to respond to trap events. The default is
<sysContact
undefined>
.
Read Community
Read community password (up to 32 characters) that authorizes an
SNMP agent to read information from the switch. This is a write-only
field. The Read Community value on the switch and the SNMP
management server must be the same. The default is
public
.
SNMP Proxy
Enables or disables the use of SNMP to monitor and configure
switches in the fabric.
Location
Specifies the name (up to 64 characters) for the switch location. The
default is
<sysLocation undefined>
.
Authentication Trap
Enables or disables the reporting of SNMP authentication failures. If
enabled, a notification trap is sent when incorrect community string
values are used. The default value is
False
.
Write Community
Write community password (up to 32 characters) that authorizes an
SNMP client to write information to the switch. This is a write-only
field. The value on the switch and the SNMP management server must
be the same. The default value is
private
.
Trap Version
Specifies the SNMP version (1 or 2) with which to format traps.
Trap 1 Enabled
Enables or disables the trap. If disabled, traps are not sent to trap
monitoring stations and the trap settings are not configurable.
Trap Address
Specifies the IP address to which SNMP traps are sent. A maximum of
5 trap addresses are supported. The default address for trap 1 is
10.0.0.254. The default address for traps 2–5 is
0.0.0.0
.
Trap Community
Trap community password (up to 32 characters) that authorizes an
SNMP agent to receive traps. This is a write-only field. The value on
the switch and the SNMP management server must be the same. The
default is
public
.
Trap Severity
Specifies a severity level to assign to the trap. Open the drop-down
list and choose a level. The Trap 1 Enabled option on the SNMP
Properties dialog box must be enabled to access this drop-down list.
Trap severity levels include Unknown, Emergency, Alert, Critical,
Error, Warning, Notify, Info, Debug, and Mark
Trap Port
Specifies the port number (between 1—65535) on which a trap is set.
The default is
162
.