HP 8/40 Brocade Access Gateway Administrator's Guide v6.3.0 (53-1001345-01, Ju - Page 71

Verifying the switch mode, Before connecting Access Gateway to classic Brocade switches

Page 71 highlights

Fabric and Edge switch configuration 4 • Disable long distance mode. • Allow multiple logins for M-EOS switches. The recommended fabric login setting is the maximum allowed per port and per switch. • Use only WWN zoning for devices behind AG. • If DCC security is being used on Edge switches that directly connect to AG, make sure to include the Access Gateway WWN or the port WWN of the N_Ports. Also include the HBA WWNs that will be connected to AG F_Ports to the ACL list in the ACL policy. It is recommended to use AG ADS policy instead of the DCC policy on the Edge switch. • Allow inband queries for forwarded fabric management requests from the hosts. Add the Access Gateway switch WWN to the access list if inband queries are restricted. Before connecting Access Gateway to classic Brocade switches, disable the Fabric OS Management Server Platform Service to get accurate statistical and configuration fabric data, Verifying the switch mode 1. Connect to the switch and log in using an account assigned to the admin role. 2. Enter the switchShow command to display the current switch configuration. The following example shows a switch in the Fabric OS Native mode where switchMode displays as Native. switch:admin> switchshow switchName: switch switchType: 43.2 switchState: Online switchMode: Native switchRole: Principal switchDomain: 1 switchId: fffc01 switchWwn: 10:00:00:05:1e:03:4b:e7 zoning: OFF switchBeacon: OFF Area Port Media Speed State Proto 0 0 -- N4 No_Module 1 1 cu N4 Online F-Port 50:06:0b:00:00:3c:b7:32 2 2 cu N4 Online F-Port 10:00:00:00:c9:35:43:f5 3 3 cu AN No_Sync 4 4 cu AN No_Sync Disabled (Persistent) 5 5 cu N4 Online F-Port 50:06:0b:00:00:3c:b4:3e 6 6 cu N4 Online F-Port 10:00:00:00:c9:35:43:f3 7 7 cu AN No_Sync Disabled (Persistent) 8 8 cu AN No_Sync 9 9 cu AN No_Sync Disabled (Persistent) 10 10 cu AN No_Sync Disabled (Persistent) 11 11 cu AN No_Sync Disabled (Persistent) 12 12 cu AN No_Sync Disabled (Persistent) 13 13 cu AN No_Sync Disabled (Persistent) 14 14 cu AN No_Sync Disabled (Persistent) 15 15 cu AN No_Sync Disabled (Persistent) 16 16 cu AN No_Sync Disabled (Persistent) 17 17 -- N4 No_Module 18 18 -- N4 No_Module 19 19 -- N4 No_Module Access Gateway Administrator's Guide 51 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

Access Gateway Administrator’s Guide
51
53-1001345-01
Fabric and Edge switch configuration
4
Disable long distance mode.
Allow multiple logins for M-EOS switches. The recommended fabric login setting is the
maximum allowed per port and per switch.
Use only WWN zoning for devices behind AG.
If DCC security is being used on Edge switches that directly connect to AG, make sure to
include the Access Gateway WWN or the port WWN of the N_Ports. Also include the HBA WWNs
that will be connected to AG F_Ports to the ACL list in the ACL policy. It is recommended to use
AG ADS policy instead of the DCC policy on the Edge switch.
Allow inband queries for forwarded fabric management requests from the hosts. Add the
Access Gateway switch WWN to the access list if inband queries are restricted.
Before connecting Access Gateway to classic Brocade switches, disable the Fabric OS Management
Server Platform Service to get accurate statistical and configuration fabric data,
Verifying the switch mode
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the
switchShow
command to display the current switch configuration.
The following example shows a switch in the Fabric OS Native mode where
switchMode
displays as Native.
switch:admin>
switchshow
switchName:
switch
switchType:
43.2
switchState:
Online
switchMode:
Native
switchRole:
Principal
switchDomain:
1
switchId:
fffc01
switchWwn:
10:00:00:05:1e:03:4b:e7
zoning:
OFF
switchBeacon:
OFF
Area Port Media Speed State
Proto
=====================================
0
0
--
N4
No_Module
1
1
cu
N4
Online
F-Port
50:06:0b:00:00:3c:b7:32
2
2
cu
N4
Online
F-Port
10:00:00:00:c9:35:43:f5
3
3
cu
AN
No_Sync
4
4
cu
AN
No_Sync
Disabled (Persistent)
5
5
cu
N4
Online
F-Port
50:06:0b:00:00:3c:b4:3e
6
6
cu
N4
Online
F-Port
10:00:00:00:c9:35:43:f3
7
7
cu
AN
No_Sync
Disabled (Persistent)
8
8
cu
AN
No_Sync
9
9
cu
AN
No_Sync
Disabled (Persistent)
10
10
cu
AN
No_Sync
Disabled (Persistent)
11
11
cu
AN
No_Sync
Disabled (Persistent)
12
12
cu
AN
No_Sync
Disabled (Persistent)
13
13
cu
AN
No_Sync
Disabled (Persistent)
14
14
cu
AN
No_Sync
Disabled (Persistent)
15
15
cu
AN
No_Sync
Disabled (Persistent)
16
16
cu
AN
No_Sync
Disabled (Persistent)
17
17
--
N4
No_Module
18
18
--
N4
No_Module
19
19
--
N4
No_Module